Become the first-class high pressure fluid control expert in the world

Suncenter  >  AI - Page Sitemap  >  easy to use oxygen pumps outlet type for natural gas boosts pressure
easy to use oxygen pumps outlet type for natural gas boosts pressure

easy to use oxygen pumps outlet type for natural gas boosts pressure
  • easy to use oxygen pumps outlet type for natural gas boosts pressure
  • easy to use oxygen pumps outlet type for natural gas boosts pressure
  • easy to use oxygen pumps outlet type for natural gas boosts pressure
  • easy to use oxygen pumps outlet type for natural gas boosts pressure
  • easy to use oxygen pumps outlet type for natural gas boosts pressure
  • easy to use oxygen pumps outlet type for natural gas boosts pressure
  • easy to use oxygen pumps outlet type for natural gas boosts pressure
  • easy to use oxygen pumps outlet type for natural gas boosts pressure

easy to use oxygen pumps outlet type for natural gas boosts pressure

Regarding the quality management of Suncenter oxygen pumps, various quality inspection systems are conducted. It must be scrutinized to check its sealing quality and whether it has any air leakage problem. It has a sturdy housing to resist accidental bumps
Get the latest price
Quantity Needed:
Pieces
E-mail:

Compressed Air Driven Gas Booster Pump- DGA/DGD/DGT Series


Suncenter Air Driven Gas Boosters provide for pressures up to 80Mpa (11,600 psi). Used for virtually all known gases, these boosters are ideal for increasing gas pressure, transferring high pressure gas, charging cylinders and scavenging. Key features include:


Applications for Air Driven Gas Boosters


SUNCENTER Air Driven Gas Boosters provide for pressures up to 80Mpa. Used for oil free compression not only of air or Nitrogen, but also flammable and risk gases like hydrogen, oxygen and natural gas. These boosters are ideal for increasing gas pressure, transferring high pressure gas, charging cylinders and scavenging.


Air driven boosters are an efficient alternative instead of electrically driven products and can be used in explosion- proof areas.


As a result of the wide range of models it is possible to select the optimum booster for each application. Single stage, double acting or two stage boosters or a combination of these models can be used to achieve different operating pressures and flow capacities.


SUNCENTER Air Driven Gas Boosters are ideal and widely used for hydrostatic and burst testing for valves, pipes, tubing and pressure vessels; Calibration for safety valves; Automobile regulator detecting and telecommunication cable inflatable appliances.


easy to use oxygen pumps outlet type for natural gas boosts pressure-1



DGA series gas booster pumps(Single acting, single air drive head):  


easy to use oxygen pumps outlet type for natural gas boosts pressure-2
  • DGA pumps are available with high quality seals, which provide significantly better service life as well. Pump head fitted with exhaust cooling devices. All parts in contact with the gas are made of stainless steel.


Model

Pressure boost ratio

Min. gas Inlet pressure PA (bar)

Max.gas Inlet pressure PA (bar)

Max. gas outlet 

pressure PB (bar)

 Driven air pressure  PL

Formula to
 calculate gas outlet pressure PB

Connection: Gas Inlet /
Gas outlet (NPT thread)

Max. flow at driven air pressure of 6bar (L/min)

DGA02

2:1

1.0

16

16

2bar-8 bar

2X PL

1/2 / 1/2

960 (at PA of 6 bar )

DGA05

5:1

0

40

40

2bar-8 bar

5XPL

1/2 / 1/2

680(at PA of 6 bar )

DGA06

6:1

2.0

48

48

2bar-8 bar

6XPL

1/2 / 1/2

360(at PA of 10 bar )

DGA10

10:1

3.5

80

80

2bar-8 bar

10XPL

3/8/ 3/8

210(at PA of 10 bar )

GA15

15:1

3.5

120

120

2bar-8 bar

15XPL

3/8/ 3/8

190(at PA of 10 bar )

DGA25

25:1

7.0

200

200

2bar-8 bar

25XPL

1/4/ 1/4

120(at PA of 20 bar )

DGA40

40:1

10

320

320

2bar-8 bar

40XPL

1/4/ 1/4

200(at PA of 40 bar )

DGA60

60:1

20 

480

480

2bar-8 bar

60XPL

1/4/ 1/4

180(at PA of 40 bar )

DGA100

100:1

25

800

800

2bar-8 bar

100XPL

1/4/ M14X1.5

136(at PA of 40 bar )


DGD series gas booster pumps(Double acting ):


easy to use oxygen pumps outlet type for natural gas boosts pressure-3
  • DGD series pumps are double acting, with single air driven heads type.   

  • DGD pumps are available with high quality seals, which provide significantly better service life

  • Double pump heads with exhaust cooling devices. 

  • All components in contact with the gas are made of stainless steel. 

  • Pipes mounting way are available as customized.


Model

Pressure boost ratio

Min. gas Inlet 

pressure PA (bar)

Max.gas Inlet 

pressure PA (bar)

Max. gas outlet 

pressure PB (bar)

 Driven air pressure PL

Formula to
calculate gas outlet pressure PB

Connection: Gas Inlet / Gas outlet (NPT thread)

Max. flow at driven air pressure of 6bar (L/min)

DGD10

10:1

3.5

80

80

2bar-8 bar

10XPL+ PA

3/8/3/8

410(at PA of 6 bar )

DGD15

15:1

5

120

120

2bar-8 bar

15XPL+ PA

3/8/3/8

350 (at PA of 6 bar )

DGD25

25:1

10

200

200

2bar-8 bar

25XPL+ PA

1/4/1/4

396(at PA of 20 bar )

DGD40

40:1

15

320

320

2bar-8 bar

40XPL+ PA

1/4/1/4

320(at PA of 40 bar )

DGD60

60:1

25

480

480

2bar-8 bar

60XPL+ PA

1/4/1/4

215(at PA of 40 bar )

DGD100

100:1

35

800

800

2bar-8 bar

100XPL+ PA

1/4/M14*1.5

300(at PA of 60 bar )

DGD130

130:1

50 

1040

1040 

2bar-8 bar

130XPL+ PA

1/4/M14*1.5

180(at PA of 60 bar )


DGT series gas booster pumps(Double acting, double stage, single air drive head ):


easy to use oxygen pumps outlet type for natural gas boosts pressure-4
  • DGT pumps are double acting, double stage with single air drive head pumps. They can provide for super high pressure with very low inlet pressure.

  • DGT pumps are available with high quality seals, which provide significantly better service life

  • All parts in contact with the gas are made of stainless steel.


Model

Pressure boost ratio

Min. gas Inlet 

pressure PA (bar)

Max.gas Inlet 

pressure PA (bar)

Max. gas outlet 

pressure PB (bar)

 Driven air pressure  

PL

Formula to calculate gas outlet pressure PB

Connection: Gas Inlet /
     Gas outlet (NPT thread)

Max. flow at driven air pressure of 6bar (L/min)

DGT15

15:1

0.1

56

120

2-8 bar

15XPL

3/8/ 1/4

230(at PA of 8 bar )

DGT25

25:1

0.1

10

200

2-8 bar

25XPL

3/8/ 1/4

156(at PA of 8 bar )

DGT7/25

25:1

5

56

200

2-8 bar

25XPL

3/8/ 1/4

156(at PA of 8 bar )

DGT40

40:1

0.1

10

320

2-8 bar

40XPL

3/8/ 1/4

124(at PA of 8 bar )

DGT15/40

40:1

5

120

320

2-8 bar

40XPL

3/8/ 1/4

124(at PA of 8 bar )

DGT60

60:1

0.1

10

480

2-8 bar

60XPL

3/8/ 1/4

80(at PA of 15 bar )

DGT15/60

60:1

6

120

480

2-8 bar

60XPL

3/8/ 1/4

80(at PA of 15 bar )

DGT100

100:1

0.1

10

800

2-8 bar

100XPL

3/8/ 1/4

63(at PA of 8 bar )



easy to use oxygen pumps outlet type for natural gas boosts pressure-5
  • DGT series gas booster working picture 


easy to use oxygen pumps outlet type for natural gas boosts pressure-6


         Gas pressure booster for cylinder transfer and filling
easy to use oxygen pumps outlet type for natural gas boosts pressure-7


         DGS series gas booster system working picture



features

  •   Compressed Air driven - no electricity required (connect to normal air compressor)  

  •   In order to extend the lifetime of the pump, the driving air pressure should not be higher than 8 bar

  •   No airline lubricator required

  •   Hydrocarbon free - separation between air and gas sections

  •    Pressures to 80Mpa (11,600 psi)

  •    Wide range of models with different ratios

  •   Built-in-cooling on most models

  •   Easy to install, operate and maintain

  •   Best price / performance ratio

  •   No heat, flame or spark risk and explosion proof 

  •   Automatic pressure holding, whatever the cause of the pressure drop, the Suncenter   pump will automatically start, keep the loop pressure constant 

  •   Applicable gas:Air/Ar(Argon)/He(Helium)/H2(Hydrogen)/O2(Oxygen)N2(Nitrogen) CO2/NO2/CH4/C2H2/LNG/LPG/CNG/FM200/SF6/H2S etc


video





The design of Suncenter oxygen pumps is completed by our professionals who adopt ergonomics principles to perfectly meet the requirements of different scenarios. It has a sturdy housing to resist accidental bumps
The R&D of Suncenter [核心关键词 is exclusively conducted by our professionals who utilize the touch-based technology to optimize the POS system according to the market trends. Processed by CNC machines, the product is highly precise
Suncenter nitrogen booster pump is strictly inspected. Not only does it have gone through a machine check on cutting, welding, and surface treatment, but also is inspected by workers. This product stands out for its exceptional durability
The raw material of Suncenter oxygen pumps is one of the oldest materials used for manufacturing different types of products used in bathrooms. Over the years, the material has proved its reliability even after excessive usage. Processed by CNC machines, the product is highly precise
Some chemicals and other additives are added to customize the Suncenter oxygen pumps for the intended use, including anhydrous aluminum silicates as reinforcing fillers. This product provides dentists and dental technicians with reliable support
Featuring elimination of any piece of paper, this product contributes a lot to the environment such as saving trees from cutting down. It can be disinfected under high temperatures
Product Message
Chat Online 编辑模式下无法使用
Chat Online inputting...