loading

Become the first-class high pressure fluid control expert in the world

Suncenter  >  AI - Page Sitemap  >  environmental fire extinguisher refill filling type for fire extinguisher
environmental fire extinguisher refill filling type for fire extinguisher

environmental fire extinguisher refill filling type for fire extinguisher
  • environmental fire extinguisher refill filling type for fire extinguisher
  • environmental fire extinguisher refill filling type for fire extinguisher
  • environmental fire extinguisher refill filling type for fire extinguisher
  • environmental fire extinguisher refill filling type for fire extinguisher
  • environmental fire extinguisher refill filling type for fire extinguisher
  • environmental fire extinguisher refill filling type for fire extinguisher

environmental fire extinguisher refill filling type for fire extinguisher

DGS-FM-5A model automatic FM200 filling machineSolution A (DGS-FM-5A) added the sensors, electromagnetic valve...
Inquire Online
Get the latest price
Quantity Needed:
Pieces
E-mail:

DGS-FM-5A model automatic FM200 filling machine


Solution A (DGS-FM-5A) added the sensors, electromagnetic valve, vacuum pump, and the electronic scale based on solution B (manual control),it is automatic control mode


environmental fire extinguisher refill filling type for fire extinguisher-1
  • Main parameters:

  • The driving source: compressed air (by air compressor, need 3-8 bar air pressure)

  • Medium: FM200/ NOVEC/Nitrogen

  • Boost ratio: 5:1

  • Output pressure: 4.2 Mpa/5.3Mpa

  • Driven air inlet port: fast insert 12 per cent

  • Nitrogen/FM200 inlet port: ZG3/8 internal thread

  • High pressure gas outlet port: ZG3/8 internal thread

  • Electric scale range:0-500kg(there is also max 1000kg for optional)


DGS-DGGD16 model liquid CO2 filling equipment


environmental fire extinguisher refill filling type for fire extinguisher-2
  • The CO2 Fire Extinguisher filling equipment including following parts:

  • Air–driven liquid CO2 gas booster pump

  • Stainless steel material cabinet

  • F.R.L combination for driven air (adjusts air pressure, add lubricating oil and water filter)

  • Driven air switch (Pump starting switch), driven air pressure gauge

  • Gas inlet switch, Gas inlet pressure gauge

  • Gas outlet switch, Gas outlet pressure gauge, unloading valve, interconnecting pipes etc.

  • And we could also customize it according to clients’special requirement.


Model

Pressure Ratio

Driven air pressure PL 

Formula to calculate outlet pressure

MAX Outlet
     Pressure(bar)*

Driven
     air inlet port

High pressure Outlet port

MAX Flow
     (L/min)**

DGS-DGG16

16:1

3-8 bar

16XPL

128

G 1/2

NPT/ZG

12.42

DGS-DGG28

28:1

3-8 bar

28XPL

224

G 1/2

NPT/ZG

7.11

DGS-DGGD166

16:1

3-8 bar

16XPL

128

G 1/2

NPT/ZG

19.73

DGS-DGGD28

28:1

3-8 bar

28XPL

224

G 1/2

NPT/ZG

11.30


DGS-CO2-B model liquid CO2(fire extinguisher) filling machine


environmental fire extinguisher refill filling type for fire extinguisher-3
  • Main parameters:

  • The driving source: compressed air (by air compressor, need 3-8 bar air pressure)

  • Medium: CO2

  • Max output pressure: 12.8Mpa

  • Driven air inlet port: fast insert 12 per cent

  • Liquid CO2 inlet port: ZG3/8 internal thread

  • High pressure gas outlet port: ZG3/8 internal thread


Fire Extinguisher filling


environmental fire extinguisher refill filling type for fire extinguisher-4
environmental fire extinguisher refill filling type for fire extinguisher-5


video





Suncenter fire extinguisher refill is processed deeply with professional techniques, including drill hole, stretch bending, milling, welding, fabrication, as well as other chemical processes. The PP raw materials and masterbatch used for it are non-toxic
Suncenter fire extinguisher filling equipment is completed after a series of the production processes, namely, mold extrusion, turning, milling, drilling, lathing, grinding, and wire cutting. Free samples can be provided for this product and will typically be shipped within one day
Suncenter fire extinguisher refill is the outcome of thermodynamics knowledge. Its whole body part especially the air circulation parts are made with special materials and circulating layout. It has passed the test of tensile strength
The design of Suncenter fire extinguisher refill is a consequence of many combined parameters. Geometry, materials, surface area design, and air velocity are all seriously considered in enhancing the performance of the product. It has passed the test of tensile strength
The production of Suncenter fire extinguisher refill consists of two parts, making processing such as extrusion, die casting, and stamping, as well as the deep process such as drilling, milling, and welding. It has good heat resistance with a melting point of 164~170 °C
We insist on using cost-effective raw materials and using automated machinery and equipment to produce fire extinguisher filling equipment, which effectively reduces the cost of raw materials, labor costs and processing costs, and promotes the wholesale price of fire extinguisher filling equipment to be at a relatively low level in the industry.
Product Message
Chat Online 编辑模式下无法使用