Become the first-class high pressure fluid control expert in the world

Suncenter  >  AI - Page Sitemap  >  environmental fire extinguisher refill station filling type for fire extinguisher
environmental fire extinguisher refill station filling type for fire extinguisher

environmental fire extinguisher refill station filling type for fire extinguisher
  • environmental fire extinguisher refill station filling type for fire extinguisher
  • environmental fire extinguisher refill station filling type for fire extinguisher
  • environmental fire extinguisher refill station filling type for fire extinguisher
  • environmental fire extinguisher refill station filling type for fire extinguisher
  • environmental fire extinguisher refill station filling type for fire extinguisher
  • environmental fire extinguisher refill station filling type for fire extinguisher

environmental fire extinguisher refill station filling type for fire extinguisher

By adopting advanced technology, the quality of this product can be assured.
Get the latest price
Quantity Needed:
Pieces
E-mail:
Application Scope
The hydro test pump developed by Suncenter Fluid Control Equipment is widely used in various fields.With a focus on customers' potential needs, Suncenter Fluid Control Equipment has the ability to provide one-stop solutions.
  • environmental fire extinguisher refill station filling type for fire extinguisher-Suncenter-img-1
Product Comparison
Suncenter Fluid Control Equipment's booster pumps has been substantially improved in a scientific way, as shown in the following aspects.
  • video-environmental fire extinguisher refill station filling type for fire extinguisher-Suncenter-im-1
    application-environmental fire extinguisher refill station filling type for fire extinguisher-Suncen-1
Company Advantages
1. fire extinguisher refill station from Dongguan Suncenter Fluid Control Equipment Co., Ltd adopts a new type of fire extinguisher refilling machine material.
2. By adopting advanced technology, the quality of this product can be assured.
3. This product perfectly matches people's personality and their outfits, which is why so many people have tried their hand at it.

DGS-FM-5A model automatic FM200 filling machine


Solution A (DGS-FM-5A) added the sensors, electromagnetic valve, vacuum pump, and the electronic scale based on solution B (manual control),it is automatic control mode


environmental fire extinguisher refill station filling type for fire extinguisher-1
  • Main parameters:

  • The driving source: compressed air (by air compressor, need 3-8 bar air pressure)

  • Medium: FM200/ NOVEC/Nitrogen

  • Boost ratio: 5:1

  • Output pressure: 4.2 Mpa/5.3Mpa

  • Driven air inlet port: fast insert 12 per cent

  • Nitrogen/FM200 inlet port: ZG3/8 internal thread

  • High pressure gas outlet port: ZG3/8 internal thread

  • Electric scale range:0-500kg(there is also max 1000kg for optional)


DGS-DGGD16 model liquid CO2 filling equipment


environmental fire extinguisher refill station filling type for fire extinguisher-2
  • The CO2 Fire Extinguisher filling equipment including following parts:

  • Air–driven liquid CO2 gas booster pump

  • Stainless steel material cabinet

  • F.R.L combination for driven air (adjusts air pressure, add lubricating oil and water filter)

  • Driven air switch (Pump starting switch), driven air pressure gauge

  • Gas inlet switch, Gas inlet pressure gauge

  • Gas outlet switch, Gas outlet pressure gauge, unloading valve, interconnecting pipes etc.

  • And we could also customize it according to clients’special requirement.


Model

Pressure Ratio

Driven air pressure PL 

Formula to calculate outlet pressure

MAX Outlet
     Pressure(bar)*

Driven
     air inlet port

High pressure Outlet port

MAX Flow
     (L/min)**

DGS-DGG16

16:1

3-8 bar

16XPL

128

G 1/2

NPT/ZG

12.42

DGS-DGG28

28:1

3-8 bar

28XPL

224

G 1/2

NPT/ZG

7.11

DGS-DGGD166

16:1

3-8 bar

16XPL

128

G 1/2

NPT/ZG

19.73

DGS-DGGD28

28:1

3-8 bar

28XPL

224

G 1/2

NPT/ZG

11.30


DGS-CO2-B model liquid CO2(fire extinguisher) filling machine


environmental fire extinguisher refill station filling type for fire extinguisher-3
  • Main parameters:

  • The driving source: compressed air (by air compressor, need 3-8 bar air pressure)

  • Medium: CO2

  • Max output pressure: 12.8Mpa

  • Driven air inlet port: fast insert 12 per cent

  • Liquid CO2 inlet port: ZG3/8 internal thread

  • High pressure gas outlet port: ZG3/8 internal thread


Fire Extinguisher filling


environmental fire extinguisher refill station filling type for fire extinguisher-4
environmental fire extinguisher refill station filling type for fire extinguisher-5


video





Company Features
1. Dongguan Suncenter Fluid Control Equipment Co., Ltd is dedicated to the manufacturing and R&D of fire extinguisher refill station .
2. The quality of fire extinguisher refill can be guaranteed by our experienced technicians.
3. We use automatic filling machine to connect the future. Please contact us! High quality customer service of Suncenter is highly commented by customers. Please contact us!
The necessary tests for Suncenter automatic filling machine have been conducted. These tests include colorfastness testing, size fitting testing, burn testing, and breathability testing. It sells well in European, the Middle East market, North Africa, and North America markets
The size of Suncenter automatic filling machine all depends on the trade-offs customers want to make, and how they want to manage a viewing experience. The strong body will not shake even when it is stirred at the highest speed
The raw materials used for Suncenter fire extinguisher refill station will be inspected in many aspects. They are tightness, wear resistance, versatility, breathability, and moisture-wicking.
Various design elements of Suncenter fire extinguisher refilling machine have been taken into account. These elements mainly include breathability, flammability, tear strength, durability, and size fitting. The swiveling multi-purpose arm with unlocking mechanism provides easy removal and installation of the bowl
Main tests have been performed during the inspection of Suncenter automatic filling machine. They are bonding test, colorfastness test (CF to light, water, and phenolic yellowing perspiration), fitting test, slip resistance test, etc. It brings consistent performance due to load-dependent electronic rotation speed control
The product has many excellent features such as optimum performance, longer service life, and so on. It is easy to clean and dishwasher safe
Product Message
Chat Online 编辑模式下无法使用
Chat Online inputting...