loading

Become the first-class high pressure fluid control expert in the world

Suncenter  >  AI - Page Sitemap  >  environmental fire extinguisher refill station filling type for fire extinguisher
environmental fire extinguisher refill station filling type for fire extinguisher

environmental fire extinguisher refill station filling type for fire extinguisher
  • environmental fire extinguisher refill station filling type for fire extinguisher
  • environmental fire extinguisher refill station filling type for fire extinguisher
  • environmental fire extinguisher refill station filling type for fire extinguisher
  • environmental fire extinguisher refill station filling type for fire extinguisher
  • environmental fire extinguisher refill station filling type for fire extinguisher
  • environmental fire extinguisher refill station filling type for fire extinguisher

environmental fire extinguisher refill station filling type for fire extinguisher

By adopting advanced technology, the quality of this product can be assured.
Get the latest price
Quantity Needed:
Pieces
E-mail:
Application Scope
The hydro test pump developed by Suncenter Fluid Control Equipment is widely used in various fields.With a focus on customers' potential needs, Suncenter Fluid Control Equipment has the ability to provide one-stop solutions.
  • environmental fire extinguisher refill station filling type for fire extinguisher-Suncenter-img-1
Product Comparison
Suncenter Fluid Control Equipment's booster pumps has been substantially improved in a scientific way, as shown in the following aspects.
  • video-environmental fire extinguisher refill station filling type for fire extinguisher-Suncenter-im-1
    application-environmental fire extinguisher refill station filling type for fire extinguisher-Suncen-1
Company Advantages
1. fire extinguisher refill station from Dongguan Suncenter Fluid Control Equipment Co., Ltd adopts a new type of fire extinguisher refilling machine material.
2. By adopting advanced technology, the quality of this product can be assured.
3. This product perfectly matches people's personality and their outfits, which is why so many people have tried their hand at it.

DGS-FM-5A model automatic FM200 filling machine


Solution A (DGS-FM-5A) added the sensors, electromagnetic valve, vacuum pump, and the electronic scale based on solution B (manual control),it is automatic control mode


environmental fire extinguisher refill station filling type for fire extinguisher-1
  • Main parameters:

  • The driving source: compressed air (by air compressor, need 3-8 bar air pressure)

  • Medium: FM200/ NOVEC/Nitrogen

  • Boost ratio: 5:1

  • Output pressure: 4.2 Mpa/5.3Mpa

  • Driven air inlet port: fast insert 12 per cent

  • Nitrogen/FM200 inlet port: ZG3/8 internal thread

  • High pressure gas outlet port: ZG3/8 internal thread

  • Electric scale range:0-500kg(there is also max 1000kg for optional)


DGS-DGGD16 model liquid CO2 filling equipment


environmental fire extinguisher refill station filling type for fire extinguisher-2
  • The CO2 Fire Extinguisher filling equipment including following parts:

  • Air–driven liquid CO2 gas booster pump

  • Stainless steel material cabinet

  • F.R.L combination for driven air (adjusts air pressure, add lubricating oil and water filter)

  • Driven air switch (Pump starting switch), driven air pressure gauge

  • Gas inlet switch, Gas inlet pressure gauge

  • Gas outlet switch, Gas outlet pressure gauge, unloading valve, interconnecting pipes etc.

  • And we could also customize it according to clients’special requirement.


Model

Pressure Ratio

Driven air pressure PL 

Formula to calculate outlet pressure

MAX Outlet
     Pressure(bar)*

Driven
     air inlet port

High pressure Outlet port

MAX Flow
     (L/min)**

DGS-DGG16

16:1

3-8 bar

16XPL

128

G 1/2

NPT/ZG

12.42

DGS-DGG28

28:1

3-8 bar

28XPL

224

G 1/2

NPT/ZG

7.11

DGS-DGGD166

16:1

3-8 bar

16XPL

128

G 1/2

NPT/ZG

19.73

DGS-DGGD28

28:1

3-8 bar

28XPL

224

G 1/2

NPT/ZG

11.30


DGS-CO2-B model liquid CO2(fire extinguisher) filling machine


environmental fire extinguisher refill station filling type for fire extinguisher-3
  • Main parameters:

  • The driving source: compressed air (by air compressor, need 3-8 bar air pressure)

  • Medium: CO2

  • Max output pressure: 12.8Mpa

  • Driven air inlet port: fast insert 12 per cent

  • Liquid CO2 inlet port: ZG3/8 internal thread

  • High pressure gas outlet port: ZG3/8 internal thread


Fire Extinguisher filling


environmental fire extinguisher refill station filling type for fire extinguisher-4
environmental fire extinguisher refill station filling type for fire extinguisher-5


video





Company Features
1. Dongguan Suncenter Fluid Control Equipment Co., Ltd is dedicated to the manufacturing and R&D of fire extinguisher refill station .
2. The quality of fire extinguisher refill can be guaranteed by our experienced technicians.
3. We use automatic filling machine to connect the future. Please contact us! High quality customer service of Suncenter is highly commented by customers. Please contact us!
Suncenter automatic filling machine is designed based on market demands and customer requirements. The product can effectively stand up to the radiation
fire extinguisher refilling machine gives a stylish, warm and lovely feel. The product is resistant to chemicals such as acids and alkalis in the body
The production process of Suncenter fire extinguisher refill follows the general method in the industry. The product features bending resistance and is not easy to break off
Suncenter fire extinguisher refilling machine is manufactured by our adroit worker by using the sophisticated equipment and advanced techniques. Its smooth wall reduces the wear and tear on the skin
Suncenter fire extinguisher refill is made using the latest technology. The product is characterized by temperature resistance
The product meets the requirements of domestic and international quality standards. The product is atraumatic and reduces tissue irritation
Product Message
Chat Online 编辑模式下无法使用
Leave Your Message inputting...