Become the first-class high pressure fluid control expert in the world

Suncenter  >  AI - Page Sitemap  >  high-energy fire extinguisher refill station co2 bulk production for fire extinguisher
high-energy fire extinguisher refill station co2 bulk production for fire extinguisher

high-energy fire extinguisher refill station co2 bulk production for fire extinguisher
  • high-energy fire extinguisher refill station co2 bulk production for fire extinguisher
  • high-energy fire extinguisher refill station co2 bulk production for fire extinguisher
  • high-energy fire extinguisher refill station co2 bulk production for fire extinguisher
  • high-energy fire extinguisher refill station co2 bulk production for fire extinguisher
  • high-energy fire extinguisher refill station co2 bulk production for fire extinguisher
  • high-energy fire extinguisher refill station co2 bulk production for fire extinguisher

high-energy fire extinguisher refill station co2 bulk production for fire extinguisher

The design of Suncenter fire extinguisher filling equipment is governed by a series of principles that emphasize rhythm, unity, balance and scale, and proportionality.
Inquire Online
Get the latest price
Quantity Needed:
Pieces
E-mail:

DGS-FM-5A model automatic FM200 filling machine


Solution A (DGS-FM-5A) added the sensors, electromagnetic valve, vacuum pump, and the electronic scale based on solution B (manual control),it is automatic control mode


high-energy fire extinguisher refill station co2 bulk production for fire extinguisher-1
  • Main parameters:

  • The driving source: compressed air (by air compressor, need 3-8 bar air pressure)

  • Medium: FM200/ NOVEC/Nitrogen

  • Boost ratio: 5:1

  • Output pressure: 4.2 Mpa/5.3Mpa

  • Driven air inlet port: fast insert 12 per cent

  • Nitrogen/FM200 inlet port: ZG3/8 internal thread

  • High pressure gas outlet port: ZG3/8 internal thread

  • Electric scale range:0-500kg(there is also max 1000kg for optional)


DGS-DGGD16 model liquid CO2 filling equipment


high-energy fire extinguisher refill station co2 bulk production for fire extinguisher-2
  • The CO2 Fire Extinguisher filling equipment including following parts:

  • Air–driven liquid CO2 gas booster pump

  • Stainless steel material cabinet

  • F.R.L combination for driven air (adjusts air pressure, add lubricating oil and water filter)

  • Driven air switch (Pump starting switch), driven air pressure gauge

  • Gas inlet switch, Gas inlet pressure gauge

  • Gas outlet switch, Gas outlet pressure gauge, unloading valve, interconnecting pipes etc.

  • And we could also customize it according to clients’special requirement.


Model

Pressure Ratio

Driven air pressure PL 

Formula to calculate outlet pressure

MAX Outlet
     Pressure(bar)*

Driven
     air inlet port

High pressure Outlet port

MAX Flow
     (L/min)**

DGS-DGG16

16:1

3-8 bar

16XPL

128

G 1/2

NPT/ZG

12.42

DGS-DGG28

28:1

3-8 bar

28XPL

224

G 1/2

NPT/ZG

7.11

DGS-DGGD166

16:1

3-8 bar

16XPL

128

G 1/2

NPT/ZG

19.73

DGS-DGGD28

28:1

3-8 bar

28XPL

224

G 1/2

NPT/ZG

11.30


DGS-CO2-B model liquid CO2(fire extinguisher) filling machine


high-energy fire extinguisher refill station co2 bulk production for fire extinguisher-3
  • Main parameters:

  • The driving source: compressed air (by air compressor, need 3-8 bar air pressure)

  • Medium: CO2

  • Max output pressure: 12.8Mpa

  • Driven air inlet port: fast insert 12 per cent

  • Liquid CO2 inlet port: ZG3/8 internal thread

  • High pressure gas outlet port: ZG3/8 internal thread


Fire Extinguisher filling


high-energy fire extinguisher refill station co2 bulk production for fire extinguisher-4
high-energy fire extinguisher refill station co2 bulk production for fire extinguisher-5


video





Suncenter fire extinguisher filling equipment is designed based on various concepts and guidance. They are mechanics, the theory of machines and mechanisms, materials science, processing technology, and so on.
The quality of Suncenter fire extinguisher refill station is absolutely correct. Our quality control team spares no effort in every step of material production, assembly, quality inspection and packaging to achieve this result.
Suncenter fire extinguisher filling equipment has a high level of quality.The QC team will carefully check the defects in weaving, loose thread and dyeing to ensure the quality.
The design of Suncenter fire extinguisher filling equipment follow these basic steps: recognition of its need or purpose, selection of a possible mechanism, analysis of forces, material selection, design of elements (sizes and stresses), detailed drawing, etc.
The quality of Suncenter fire extinguisher refill station is tested. It has been tested for strength, ductility, impact resistance, hardness, and fracture toughness.
We have a complete cost control system and insist on strictly controlling the production cost of each link of fire extinguisher refill station, so that the final production fire extinguisher refill station has a higher cost performance.
Product Message