Become the first-class high pressure fluid control expert in the world

Suncenter  >  AI - Page Sitemap  >  high quality gas booster compressor bench for-sale for safety valve calibration
high quality gas booster compressor bench for-sale for safety valve calibration

high quality gas booster compressor bench for-sale for safety valve calibration
  • high quality gas booster compressor bench for-sale for safety valve calibration
  • high quality gas booster compressor bench for-sale for safety valve calibration
  • high quality gas booster compressor bench for-sale for safety valve calibration
  • high quality gas booster compressor bench for-sale for safety valve calibration

high quality gas booster compressor bench for-sale for safety valve calibration

Gas booster pressure test benchSuncenter - Air/Gas pressure test bench are compact and delicacy solution...
Inquire Online
Get the latest price
Quantity Needed:
Pieces
E-mail:
Company Advantages
1. The design of Suncenter gas booster compressor is completed by a dedicated technical team of CAD/CAM designers and structural engineers who try to design a long-lasting tent. It can be tailored to meet the specific requirements of customers
2. It works as a creative and ingenious solution in maximizing the space, making the space functional, impacting the quality of life of its occupants, and aesthetically pleasing. This product features energy saving and environmental protection
3. The product does no harm to the body. The ingredients are tested to be free from hazardous substance without affecting the body's structure or functions. Its special design can effectively eliminate the dangers

Gas booster pressure test bench


Suncenter - Air/Gas pressure test bench are compact and delicacy solution tailored to customer specific requirements with gas(air) boosters as well as all accessories to be fitted and installed in the frame or a closed cabinet.


To operate this system, the pressure gauges, valves and pressure regulators have to be fitted on panels. The outlet pressure is easily to be set through a simple air regulator.


The pump stops automatically when this end pressure is reached and restarts with a slight drop in the outlet pressure or an increase in the air drive pressure.


Operating pressure up to 80 MPa, for higher pressure, pump with double driven heads is an ideal option.


high quality gas booster compressor bench for-sale for safety valve calibration-1



The hottest selling- Model C frame type cabinet picture


high quality gas booster compressor bench for-sale for safety valve calibration-2
  • The standard gas booster pumps system including following parts:

  • Air –driven gas booster pump (DGA/DGD/DGT three series for choosing)

  • Stainless steel (carbon steel) material cabinet (Three models for choosing)

  • F.R.L combination for driven air (adjusts air pressure, add lubricating oil and water filter)

  • Driven air switch (Pump starting switch), driven air pressure gauge

  • Gas inlet switch, Gas inlet pressure gauge

  • Gas outlet switch, Gas outlet pressure gauge,  unloading valve, interconnecting pipes etc.

  • And we could also customize it according to clients’ special requirement.


high quality gas booster compressor bench for-sale for safety valve calibration-3
  • DGS series air/gas pressure test bench with round chart recorder


Model

Pressure boost ratio

Min. gas
Inlet pressure
PA (bar)

Max.gas
Inlet pressure
PA (bar)

Max. gas
outlet pressure PB (bar)

 Driven air pressure  PL

Formula to
calculate gas outlet pressure PB

Connection:
Gas Inlet /
Gas outlet (ZG thread)

Max. flow at driven air pressure of 6bar (L/min)

DGS-DGA02

2:1

1.0

16

16

2-8 bar

2X PL

1/2 / 1/2

960 (at PA of 6 bar )

DGS-DGA05

5:1

0

40

40

2-8 bar

5XPL

1/2 / 1/2

680(at PA of 6 bar )

DGS-DGA10

10:1

3.5

80

80

2-8 bar

10XPL

3/8/ 3/8

210(at PA of 10 bar )

DGS-DGA25

25:1

7.0

200

200

2-8 bar

25XPL

1/4/ 1/4

120(at PA of 20 bar )

DGS-DGA40

40:1

10

320

320

2-8 bar

40XPL

1/4/ 1/4

200(at PA of 40 bar )

DGS-DGA60

60:1

20

480

480

2-8 bar

60XPL

1/4/ 1/4

180(at PA of 40 bar )

DGS-DGA100

100:1

25

800

800

2-8 bar

100XPL

1/4/ M14X1.5

136(at PA of 40 bar )

DGS-DGA130

130:1

35

800

1040

2-8 bar

130XPL

1/4/ M14X1.5

120(at PA of 40 bar )


Technical specification for DGS-DGD series


Model

Pressure boost ratio

Min. gas
Inlet pressure
PA (bar)

Max.gas
Inlet pressure
PA (bar)

Max. gas 

outlet pressure PB (bar)

 Driven air pressure  PL

Formula to
calculate gas outlet pressure PB

Connection:
Gas Inlet /
Gas outlet (ZG thread)

Max. flow at driven air pressure of 6bar (L/min)

DGS-DGD10

10:1

3.5

80

80

2-8 bar

10XPL+ PA

3/8/3/8

410(at PA of 6 bar )

DGS-DGD25

25:1

10

200

200

2-8 bar

25XPL+ PA

1/4/1/4

396(at PA of 20 bar )

DGS-DGD40

40:1

15

320

320

2-8 bar

40XPL+ PA

1/4/1/4

320(at PA of 40 bar )

DGS-DGD60

60:1

25

480

480

2-8 bar

60XPL+ PA

1/4/1/4

215(at PA of 40 bar )

DGS-DGD100

100:1

35

800

800

2-8 bar

100XPL+ PA

1/4/M14*1.5

300(at PA of 60 bar )


Technical specification for DGS-DGT series


Model

Pressure boost ratio

Min. gas
Inlet pressure
PA (bar)

Max.gas
Inlet pressure
PA (bar)

Max. gas
outlet pressure PB (bar)

 Driven air pressure  PL

Formula to
calculate gas outlet pressure PB

Connection:
Gas Inlet /
Gas outlet (ZG thread)

Max. flow at driven air pressure of 6bar (L/min)

DGS-DGT25

25:1

0.1

10

200

 2-8 bar

25XPL+3.5XPA

1/4/ 1/4

136(at PA of 8 bar )

DGS-DGT40

40:1

0.1

10

320

2-8 bar

40XPL+ 6XPA

 1/4/1/4

124(at PA of 8 bar )

 DGS-DGT10/60

10:1/60:1

0.1

10

480

2-8 bar

60XPL+6X PA

 1/4/1/4

84(at PA of 8 bar )

DGS-DGT25/60

25:1/60:1

10

25

480

2-8 bar

60XPL+2.5XPA

 1/4/1/4

80(at PA of 15 bar )

DGS-DGT100

100:1

0.1

10

800

2-8 bar

100XPL+10XPA

1/4/ M14*1.5

63(at PA of 8 bar )


video





Company Features
1. It turns out to be effective that Dongguan Suncenter Fluid Control Equipment Co., Ltd has been putting a lot of investment into producing gas booster compressor with great performance.
2. The company is dedicated to employees' growth. It provides employees with the opportunity to learn how to run a business, provide excellent customer service, and take on new challenges. Get price!
Suncenter gas booster compressor has passed a wide range of tests. They include statics testing, dynamics testing, materials strength testing, vibration testing, reliability testing, and fatigue testing. We are quality-oriented in Jiabang
The design principles of Suncenter gas booster compressor mainly include the following aspects: stiffness and rigidity of the separate constructional elements and their combined behavior under load as well as operational movements. We are quality-oriented in Jiabang
Suncenter gas booster compressor has been tested for electrical components and accessories, including adaptors, cables, electrical panels, extension cords, external power supply, power supply, etc. You even don't need any adhesive or cement during the process of splicing our decking tiles
Suncenter pneumatic test bench is the outcome of complicated electric knowledge. It is developed taking many things into consideration, including the design of circuit boards, components, circuits, and the whole product shape. We export our products to many countries, including Japan, US, Middle East and etc
Suncenter gas booster compressor is made from quality materials that come with written certification from the supplier stating it meets the flame resistance requirements and providing the lot number and test results. Foshan Jiabang Garden Supplies Co., Ltd set up in 2004
Our product has special features like high performance and long service life. Our company has successfully got several patents for technology
Product Message
Chat Online 编辑模式下无法使用
Leave Your Message inputting...