loading

Become the first-class high pressure fluid control expert in the world

Suncenter  >  AI - Page Sitemap  >  high reputation liquid nitrogen pump booster effectively for pressurization
high reputation liquid nitrogen pump booster effectively for pressurization

high reputation liquid nitrogen pump booster effectively for pressurization
  • high reputation liquid nitrogen pump booster effectively for pressurization
  • high reputation liquid nitrogen pump booster effectively for pressurization
  • high reputation liquid nitrogen pump booster effectively for pressurization
  • high reputation liquid nitrogen pump booster effectively for pressurization
  • high reputation liquid nitrogen pump booster effectively for pressurization
  • high reputation liquid nitrogen pump booster effectively for pressurization
  • high reputation liquid nitrogen pump booster effectively for pressurization

high reputation liquid nitrogen pump booster effectively for pressurization

The product is exceptional in terms of durability and requires the least maintenance.
Get the latest price
Quantity Needed:
Pieces
E-mail:
Product Comparison
Suncenter Fluid Control Equipment's hydro test pump has better quality than other products in the industry, which is specifically shown in the following aspects.
  • video-high reputation liquid nitrogen pump booster effectively for pressurization-Suncenter-img-1
    application-high reputation liquid nitrogen pump booster effectively for pressurization-Suncenter-im-1
Company Advantages
1. Suncenter co2 fire extinguisher filling pump is meticulously crafted. Its manufacturing process is based on a high level of expertise in creative development, engineering, and printing.
2. The product is exceptional in terms of durability and requires the least maintenance.
3. Dongguan Suncenter Fluid Control Equipment Co., Ltd provide our customers with more high quality, cheap liquid nitrogen pump and excellent service.
4. The product superiority helps strengthen brand share.

Compressed Air Driven Liquid Gas Booster Pump-DGG/DGGD Series


SUNCENTER pumps are air driven at a drive air pressure of 2 to 10bar (29 to145 psi) by the normal air compressor. Basically the principle of operation is similar to a reciprocating amplifier where control of the piston at the end position is regulated by a pilot operated 4/2 way valve.


Suncenter pumps feature a large air piston joint to a smaller diameter plunger. The pressure ratio is the difference of these two areas and is the method of determining maximum outlet pressure. Higher pressures obtained by using higher pressure ratios.Suncenter model numbers reflect the pumps nominal pressure ratios, while the technical data indicates exact ratios. The outlet pressure is easily to set through a simple air regulator. By multiplying the pressure ratio by the available shop air pressure, the nominal outlet pressure can be calculated.


high reputation liquid nitrogen pump booster effectively for pressurization-1



DGG Series Liquid Gas Booster Pumps


high reputation liquid nitrogen pump booster effectively for pressurization-2
  • DGG Series Liquid Gas Booster Pumps  


Model

Pressure  Boost Ratio

Driven air pressure PL 

Formula to calculate outlet pressure

MAX Outlet
     Pressure(bar)*

Liquid inlet Connection

Liquid outlet Connection

MAX Flow (L/min) 

DGG6

6:1

3-8 bar

6XPL

48

NPT1/2

NPT1/2

29.91

DGG10

10:1

3-8 bar

10XPL

80

NPT1/2

NPT1/2

18.84

DGG16

16:1

3-8 bar

16XPL

128

NPT1/2

NPT1/2

12.42

DGG28

28:1

3-8 bar

28XPL

224

NPT1/2

NPT1/2

7.11

DGG40

40:1

3-8 bar

40XPL

320

NPT1/2

NPT1/2

4.89

DGG64

64:1

3-8 bar

64XPL

512

NPT1/2

NPT3/8

3.08

DGG80

80:1

3-8 bar

80XPL

640

NPT1/2

NPT3/8

2.44

DGG100

100:1

3-8 bar

100XPL

800

NPT1/2

NPT3/8

1.92


DGGD Series Liquid Gas Pumps(Double acting)


high reputation liquid nitrogen pump booster effectively for pressurization-3
  • DGGD Series Liquid Gas Pumps(Double acting) 


Model

Pressure  Boost Ratio

Driven air pressure PL 

Formula to calculate outlet pressure

MAX Outlet
     Pressure(bar)*

Liquid inlet Connection

Liquid outlet Connection

MAX Flow (L/min)**

DGGD4

4:1

3-8 bar

4XPL

32

NPT1/2

NPT1/2

70.00

DGGD6

6:1

3-8 bar

6XPL

48

NPT1/2

NPT1/2

48.60

DGGD10

10:1

3-8 bar

10XPL

80

NPT1/2

NPT1/2

30.61

DGGD16

16:1

3-8 bar

16XPL

128

NPT1/2

NPT1/2

19.73

DGGD28

28:1

3-8 bar

28XPL

224

NPT1/2

NPT1/2

11.30

DGGD40

40:1

3-8 bar

40XPL

320

NPT1/2

NPT3/8

7.69

DGGD64

64:1

3-8 bar

64XPL

512

NPT1/2

NPT3/8

4.94

DGGD80

80:1

3-8 bar

80XPL

640

NPT1/2

NPT3/8

3.96

DGGD100

100:1

3-8 bar

100XPL

800

NPT1/2

NPT3/8

3.13



Suncenter DLS Series liquid gas filling booster pump system


SUNCENTER- Liquid gas filling pump systems are compact and delicacy solution tailored to customer specific requirements with air driven pumps as well as all accessories to be fitted and installed on the frame or in closed cabinet.


To operate this system, the pressure gauges, valves and pressure regulators have to be fitted on panels. The outlet pressure is easily to be set through a simple air regulator. The pump stops automatically when this end pressure is reached and restarts with a slight drop in the outlet pressure or an increase in the air drive pressure.


As the pressure will be generated by means of a pneumatically operated pump,the electric connection will not be necessary. To operate this system, the air driven pump have to be equipped with the air control unit combined filter, pressure-regulating valve, pressure control gauge as well as manual relieve valve. In this operation, the pump will be mounted to the stainless steel tank in the closed cabinet in a compact and space saving manner. Pressure gauges, valves and pressure regulators will be fitted on panel.


high reputation liquid nitrogen pump booster effectively for pressurization-4


DLS liquid gas booster system = liquid gas booster pump+ following valves, gages, and parts



high reputation liquid nitrogen pump booster effectively for pressurization-5


The hottest selling- Model C cabinet picture


high reputation liquid nitrogen pump booster effectively for pressurization-6
  • The standard gas booster pumps system including following parts:

  • Air –driven liquid N2O/CO2/NOVEC/Refrigerant gas booster pump

  • Stainless steel (carbon steel) material cabinet

  • F.R.L combination for driven air (adjusts air pressure, add lubricating oil and water filter)

  • Driven air switch (Pump starting switch), driven air pressure gauge

  • Gas inlet switch, Gas inlet pressure gauge

  • Gas outlet switch, Gas outlet pressure gauge, unloading valve, interconnecting pipes etc.

  • And we could also customize it according to clients’ special requirement.


Model

Pressure Ratio

Driven air pressure PL 

Formula to calculate outlet pressure

MAX Outlet
     Pressure(bar)*

Driven
     air inlet    port

High pressure Outlet port

MAX Flow
     (L/min)**

DLS-DGG6

6:1

3-8 bar

6XPL

48

G 1/2

NPT/ZG

29.91

DLS-DGG10

10:1

3-8 bar

10XPL

80

G 1/2

NPT/ZG

18.84

DLS-DGG16

16:1

3-8 bar

16XPL

128

G 1/2

NPT/ZG

12.42

DLS-DGG28

28:1

3-8 bar

28XPL

224

G 1/2

NPT/ZG

7.11

DLS-DGG40

40:1

3-8 bar

40XPL

320

G 1/2

NPT/ZG

4.89

DLS-DGG64

64:1

3-8 bar

64XPL

512

G 1/2

NPT/ZG

3.08

DLS-DGG80

80:1

3-8 bar

80XPL

640

G 1/2

NPT/ZG

2.44

DLS-DGG100

100:1

3-8 bar

100XPL

800

G 1/2

NPT/ZG

1.92


DLS-DGGD series Liquid gas booster system technical specification


Model

Pressure Ratio

Driven air pressure PL 

Formula to calculate outlet pressure

MAX Outlet
     Pressure(bar)*

Driven
     air inlet    port

High pressure Outlet port

MAX Flow
     (L/min)**

DLS-DGGD4

4:1

3-8 bar

4XPL

32

G 1/2

NPT/ZG

70.00

DLS-DGGD6

6:1

3-8 bar

6XPL

48

G 1/2

NPT/ZG

48.60

DLS-DGGD10

10:1

3-8 bar

10XPL

80

G 1/2

NPT/ZG

30.61

DLS-DGGD16

16:1

3-8 bar

16XPL

128

G 1/2

NPT/ZG

19.73

DLS-DGGD28

28:1

3-8 bar

28XPL

224

G 1/2

NPT/ZG

11.30

DLS-DGGD40

40:1

3-8 bar

40XPL

320

G 1/2

NPT/ZG

7.69

DLS-DGGD64

64:1

3-8 bar

64XPL

512

G 1/2

NPT/ZG

4.94

DLS-DGGD80

80:1

3-8 bar

80XPL

640

G 1/2

NPT/ZG

3.96

DLS-DGGD100

100:1

3-8 bar

100XPL

800

G 1/2

NPT/ZG

3.13



features

  •   Compressed Air driven - no electricity required (connect to normal air compressor)

  •   In order to extend the lifetime of the pump, the driving air pressure should not be higher than 8 bar

  •   No airline lubricator required

  •   Wide range of models with different ratios

  •   Built-in-cooling on most models

  •   Easy to install, operate and maintain

  •   Best price / performance ratio

  •   No heat, flame or spark risk and explosion proof

  •   Automatic pressure holding, whatever the cause of the pressure drop, the Suncenter booster pump will automatically start, keep the loop pressure constant

  •   Applicable for various kinds of gas such as N2O/CO2/NOVEC/Refrigerant etc.

  •   For liquid gas(liquid+gas mixture) cylinder transfer/filling/recovery

  •  For CO2 Fire Extinguisher filling 

  •   For Supercritical CO2 extraction


video





Company Features
1. Dongguan Suncenter Fluid Control Equipment Co., Ltd is a qualified manufacturer and supplier of co2 fire extinguisher filling pump . We excel in developing, designing, and providing high-quality products.
2. We introduced advanced liquid nitrogen pump equipment, which produce high quality products with sophisticated design and fine finish.
3. For these years, Dongguan Suncenter Fluid Control Equipment Co., Ltd scrupulously abide by the tenet of co2 cylinder filling pump . Get info! high pressure booster pump is the driving force for Dongguan Suncenter Fluid Control Equipment Co., Ltd. Get info! Providing 'competitive and affordable' liquid co2 pumps is always Dongguan Suncenter Fluid Control Equipment Co., Ltd's direction. Get info! Dongguan Suncenter Fluid Control Equipment Co., Ltd will persist in continuously optimizing the the quality booster pump price . Get info!
booster pump price is manufactured by the material of co2 cylinder filling pump. This product is distinguished for its almost zero magnetostriction
These unique ideas, styles, and design features will add personality to your co2 cylinder filling pump. The product has excellent thermal stability, working stably from a wide temperature range
The selection of co2 fire extinguisher filling pump depends on the quality of liquid nitrogen pump to a large extent. The product has been tested under frequent current measurements
Such structures of co2 cylinder filling pump are characterized by liquid nitrogen pump. The unrivaled magnetic properties are counted as its most prominent feature
Our co2 fire extinguisher filling pump are in various style, including co2 fire extinguisher filling pump. Its thickness can be customized based on requirements
Our professional and skilled quality controllers carefully inspect the product at every step of the production process to ensure that its quality remains excellent without any defects. The core finishing can be the plastic case or metal case
Product Message
Chat Online 编辑模式下无法使用
Leave Your Message inputting...