Become the first-class high pressure fluid control expert in the world

sales@chinasuncenter.com

high reputation pump booster gas for natural gas boosts pressure-Suncenter-imgEnglish
Suncenter  >  AI - Page Sitemap  >  high reputation pump booster gas for natural gas boosts pressure
high reputation pump booster gas for natural gas boosts pressure

high reputation pump booster gas for natural gas boosts pressure
  • high reputation pump booster gas for natural gas boosts pressure
  • high reputation pump booster gas for natural gas boosts pressure
  • high reputation pump booster gas for natural gas boosts pressure
  • high reputation pump booster gas for natural gas boosts pressure

high reputation pump booster gas for natural gas boosts pressure

Testings for Suncenter oxygen booster pump are done to meet physical and chemical properties requirements for furniture. The product has passed the tests such as stability, strength, aging, colorfastness, and flame retardance. It is widely used in carton sealing, auto-packing, bundling and strapping
Get the latest price
Quantity Needed:
Pieces
E-mail:

Compressed Air Driven Gas Booster Pump- DGT Series


Suncenter Air Driven Gas Boosters provide for pressures up to 80Mpa (11,600 psi). Used for virtually all known gases, these boosters are ideal for increasing gas pressure, transferring high pressure gas, charging cylinders and scavenging. Key features include:


Applications for Air Driven Gas Boosters


SUNCENTER Air Driven Gas Boosters provide for pressures up to 80Mpa. Used for oil free compression not only of air or Nitrogen, but also flammable and risk gases like hydrogen, oxygen and natural gas. These boosters are ideal for increasing gas pressure, transferring high pressure gas, charging cylinders and scavenging.


Air driven boosters are an efficient alternative instead of electrically driven products and can be used in explosion- proof areas.


As a result of the wide range of models it is possible to select the optimum booster for each application. Single stage, double acting or two stage boosters or a combination of these models can be used to achieve different operating pressures and flow capacities.


SUNCENTER Air Driven Gas Boosters are ideal and widely used for hydrostatic and burst testing for valves, pipes, tubing and pressure vessels; Calibration for safety valves; Automobile regulator detecting and telecommunication cable inflatable appliances.


high reputation pump booster gas for natural gas boosts pressure-1



DGT series gas booster pumps(Double acting, double stage, single air drive head ):


high reputation pump booster gas for natural gas boosts pressure-2
  • DGT pumps are double acting, double stage with single air drive head pumps. They can provide for super high pressure with very low inlet pressure.  

  • DGT pumps are available with high quality seals, which provide significantly better service life  

  • All parts in contact with the gas are made of stainless steel. 


Model

Pressure boost ratio

Min. gas
Inlet pressure
PA (bar)

Max.gas
Inlet pressure
PA (bar)

Max. gas
outlet pressure PB (bar)

 Driven air pressure  PL

Formula to
calculate gas outlet pressure PB

Connection:
Gas Inlet /
Gas outlet (NPT thread)

Max. flow at driven air pressure of 6bar (L/min)

DGT15

15:1

0.1

56

120

2-8 bar

15XPL

3/8/ 1/4

230(at PA of 8 bar )

DGT25

25:1

0.1

10

200

2-8 bar

25XPL

3/8/ 1/4

156(at PA of 8 bar )

DGT7/25

25:1

5

56

200

2-8 bar

25XPL

3/8/ 1/4

156(at PA of 8 bar )

DGT40

40:1

0.1

10

320

2-8 bar

40XPL

3/8/ 1/4

124(at PA of 8 bar )

DGT15/40

40:1

5

120

320

2-8 bar

40XPL

3/8/ 1/4

124(at PA of 8 bar )

DGT60

60:1

0.1

10

480

2-8 bar

60XPL

3/8/ 1/4

80(at PA of 15 bar )

DGT15/60

60:1

6

120

480

2-8 bar

60XPL

3/8/ 1/4

80(at PA of 15 bar )

DGT100

100:1

0.1

10

800

2-8 bar

100XPL

3/8/ 1/4

63(at PA of 8 bar )


2DGT series gas booster pumps(Double acting, double stage,double air driven heads ):


high reputation pump booster gas for natural gas boosts pressure-3
  • 2DGT series gas booster pumps(Double acting, double stage,double air driven heads ) 


Model

Pressure boost ratio

Min. gas
Inlet pressure
PA (bar)

Max.gas
Inlet pressure
PA (bar)

Max. gas
outlet pressure PB (bar)

 Driven air pressure  PL

Formula to
calculate gas outlet pressure PB

Connection:
Gas Inlet /
Gas outlet (NPT thread)

Max. flow at driven air pressure of 6bar (L/min)

2DGT7/15

15:1

4

56

120

2bar-8 bar

15XPL

3/8 / 3/8

430(at PA of 10 bar )

2DGT7/25

25:1

5

56

200

2bar-8 bar

25XPL

3/8 / 3/8

300(at PA of 10 bar )

2DGT15/40

40:1

7

120

320

2bar-8 bar

40XPL

3/8 / 3/8

180(at PA of 10 bar )

2DGT15/60

60:1

7

120

480

2bar-8 bar

60XPL

3/8 / 3/8

120(at PA of 10 bar )



features

  •   Compressed Air driven - no electricity required (connect to normal air compressor)

  •   In order to extend the lifetime of the pump, the driving air pressure should not be higher than 8 bar  

  •   No airline lubricator required

  •   Hydrocarbon free - separation between air and gas sections

  •   Pressures to 80Mpa (11,600 psi)

  •   Wide range of models with different ratios

  •   Built-in-cooling on most models

  •   Easy to install, operate and maintain

  •   Best price / performance ratio

  •   No heat, flame or spark risk and explosion proof  

  •   Automatic pressure holding, whatever the cause of the pressure drop, the Suncenter   pump will automatically start, keep the loop pressure constant 

  •   Applicable gas:Air/Ar(Argon)/He(Helium)/H2(Hydrogen)/O2(Oxygen)N2(Nitrogen) CO2/NO2/CH4/C2H2/LNG/LPG/CNG/FM200/SF6/H2S etc


video





The design of Suncenter oxygen booster pump is the outcome of high-tech and humanized orientation. The designers work with the current kitchen design to produce user-friendly cabinetry and enhance the beauty of the kitchen.
The design of Suncenter oxygen booster pump is sophisticated. It is an outcome of a better understanding of science, ergonomics, comfort, production, and the business of marketing. With good weatherability, it is resistant to temperature and moisture
Various design elements of Suncenter oxygen booster pump have been taken into account. These elements mainly include breathability, flammability, tear strength, durability, and size fitting. It comes with the general purpose and high-temperature series
The design of Suncenter pump booster is people-oriented. It considers the human body shape, comfort level, materials safety, convenience, and other essential functions such as breathability and wears resistance. It is not likely to lose adhesion over time
The design of Suncenter pump booster is professional. It is completed by our professional designers who always follow the latest trends in furniture design. It has good insulation and flame resistance
What's more, Suncenter also takes oxygen booster pump into serious consideration to achieving a green living. The product is perfect for the prevention of cargo theft and illegal opening
Product Message
Chat Online inputting...