Become the first-class high pressure fluid control expert in the world

Suncenter  >  AI - Page Sitemap  >  new-arrival fire extinguisher refill station cylinder bulk production for fire extinguisher
new-arrival fire extinguisher refill station cylinder bulk production for fire extinguisher

new-arrival fire extinguisher refill station cylinder bulk production for fire extinguisher
  • new-arrival fire extinguisher refill station cylinder bulk production for fire extinguisher
  • new-arrival fire extinguisher refill station cylinder bulk production for fire extinguisher
  • new-arrival fire extinguisher refill station cylinder bulk production for fire extinguisher
  • new-arrival fire extinguisher refill station cylinder bulk production for fire extinguisher
  • new-arrival fire extinguisher refill station cylinder bulk production for fire extinguisher
  • new-arrival fire extinguisher refill station cylinder bulk production for fire extinguisher

new-arrival fire extinguisher refill station cylinder bulk production for fire extinguisher

DGS-FM-5A model automatic FM200 filling machineSolution A (DGS-FM-5A) added the sensors, electromagnetic valve...
Get the latest price
Quantity Needed:
Pieces
E-mail:
Company Advantages
1. The quality of Suncenter automatic liquid filling machine is guaranteed through all the production stages by the QC team, so as to meet the international mechanical seal standards. The product can be mounted in any position
2. The product has earned a good reputation in the market and will be applied more in the future. This product has a compact and robust design
3. fire extinguisher refill station is equipped with an advanced heat exchanger to greatly improve the heat exchange efficiency of the evaporator. Moreover, it has a variety of protection functions. It is of good durability and reliable safety.
4. fire extinguisher refill station is made up of high-quality components. It has not only has extremely high heat exchange efficiency, but also has excellent temperature resistance and long service life.
5. fire extinguisher refill station is equipped with an advanced heat exchanger. This increases the heat exchange area, enhances fluid perturbation, and effectively improves heat transfer efficiency.

DGS-FM-5A model automatic FM200 filling machine


Solution A (DGS-FM-5A) added the sensors, electromagnetic valve, vacuum pump, and the electronic scale based on solution B (manual control),it is automatic control mode


new-arrival fire extinguisher refill station cylinder bulk production for fire extinguisher-1
  • Main parameters:

  • The driving source: compressed air (by air compressor, need 3-8 bar air pressure)

  • Medium: FM200/ NOVEC/Nitrogen

  • Boost ratio: 5:1

  • Output pressure: 4.2 Mpa/5.3Mpa

  • Driven air inlet port: fast insert 12 per cent

  • Nitrogen/FM200 inlet port: ZG3/8 internal thread

  • High pressure gas outlet port: ZG3/8 internal thread

  • Electric scale range:0-500kg(there is also max 1000kg for optional)


DGS-DGGD16 model liquid CO2 filling equipment


new-arrival fire extinguisher refill station cylinder bulk production for fire extinguisher-2
  • The CO2 Fire Extinguisher filling equipment including following parts:

  • Air–driven liquid CO2 gas booster pump

  • Stainless steel material cabinet

  • F.R.L combination for driven air (adjusts air pressure, add lubricating oil and water filter)

  • Driven air switch (Pump starting switch), driven air pressure gauge

  • Gas inlet switch, Gas inlet pressure gauge

  • Gas outlet switch, Gas outlet pressure gauge, unloading valve, interconnecting pipes etc.

  • And we could also customize it according to clients’special requirement.


Model

Pressure Ratio

Driven air pressure PL 

Formula to calculate outlet pressure

MAX Outlet
     Pressure(bar)*

Driven
     air inlet port

High pressure Outlet port

MAX Flow
     (L/min)**

DGS-DGG16

16:1

3-8 bar

16XPL

128

G 1/2

NPT/ZG

12.42

DGS-DGG28

28:1

3-8 bar

28XPL

224

G 1/2

NPT/ZG

7.11

DGS-DGGD166

16:1

3-8 bar

16XPL

128

G 1/2

NPT/ZG

19.73

DGS-DGGD28

28:1

3-8 bar

28XPL

224

G 1/2

NPT/ZG

11.30


DGS-CO2-B model liquid CO2(fire extinguisher) filling machine


new-arrival fire extinguisher refill station cylinder bulk production for fire extinguisher-3
  • Main parameters:

  • The driving source: compressed air (by air compressor, need 3-8 bar air pressure)

  • Medium: CO2

  • Max output pressure: 12.8Mpa

  • Driven air inlet port: fast insert 12 per cent

  • Liquid CO2 inlet port: ZG3/8 internal thread

  • High pressure gas outlet port: ZG3/8 internal thread


Fire Extinguisher filling


new-arrival fire extinguisher refill station cylinder bulk production for fire extinguisher-4
new-arrival fire extinguisher refill station cylinder bulk production for fire extinguisher-5


video





Company Features
1. Dongguan Suncenter Fluid Control Equipment Co., Ltd is internationally competitive in the fire extinguisher refill station market. Our factory has implemented the recognized Quality Management System. This allows us to get full traceability of our products and constantly monitor our manufacturing processes.
2. Over the years, we have expanded a broad marketing channel all over the world and we have accumulated and established a strong customer base in foreign markets. This makes us stay ahead of the other peer competitors.
3. Our factory is strategically located. It allows us to acquire a variety of technical and support talents that help us in our mission to provide excellent manufacturing services. Dongguan Suncenter Fluid Control Equipment Co., Ltd always set high demand on its staff to provide best service for our customers. Inquire now!
The production of Suncenter fire extinguisher refill station conforms with the norms and guidelines defined by the market. The product features a high level of acid and alkali resistance
Suncenter fire extinguisher refill station represents the finest workmanship in the market as it is manufactured using the leading technology. The product features a high level of acid and alkali resistance
Suncenter automatic liquid filling machine is made of the finest materials that has passed the international tests. The components of the product are characterized by enhanced sturdiness and wear resistance
Featuring functionality the offered Suncenter fire extinguisher refill station is one of the best selling products in the our ranges. It has the ability to tolerate greater tension than other suchlike
Thanks to our cutting-edge technology, Suncenter fire extinguisher refill station is produced in high efficiency. It shows high tensile strength in the face of impact and collision
The strict quality control system is applied to ensure the quality of the product. It has undergone strict tests including salt spray and nitric acid test
Product Message
Chat Online 编辑模式下无法使用
Leave Your Message inputting...