loading

Become the first-class high pressure fluid control expert in the world

Suncenter  >  AI - Page Sitemap  >  specialsafety fire extinguisher refill station co2 for fire extinguisher
specialsafety fire extinguisher refill station co2 for fire extinguisher

Specialsafety fire extinguisher refill station co2 for fire extinguisher

MOQ
1 Set
Brand Name
SUNCENTER
Certificate
ISO/CE/SGS
Warranty
13 Months
Packaging
By Plywood case
Shipping Port
Shenzhen/Hongkong
Payment
T/T,Western Union,Credit card.
Transaction method
EXW,FOB,DDP,CIF,CFR
Place of Origin
Guangdong Province, China (Mainland)
Delivery Time
Within 10-15 working days after received deposit
Price
Get Latest Price
Get the latest price
Quantity Needed:
Pieces
E-mail:

DGS-FM-5A model automatic FM200 filling machine


Solution A (DGS-FM-5A) added the sensors, electromagnetic valve, vacuum pump, and the electronic scale based on solution B (manual control),it is automatic control mode


specialsafety fire extinguisher refill station co2 for fire extinguisher-1
  • Main parameters:

  • The driving source: compressed air (by air compressor, need 3-8 bar air pressure)

  • Medium: FM200/ NOVEC/Nitrogen

  • Boost ratio: 5:1

  • Output pressure: 4.2 Mpa/5.3Mpa

  • Driven air inlet port: fast insert 12 per cent

  • Nitrogen/FM200 inlet port: ZG3/8 internal thread

  • High pressure gas outlet port: ZG3/8 internal thread

  • Electric scale range:0-500kg(there is also max 1000kg for optional)


DGS-DGGD16 model liquid CO2 filling equipment


specialsafety fire extinguisher refill station co2 for fire extinguisher-2
  • The CO2 Fire Extinguisher filling equipment including following parts:

  • Air–driven liquid CO2 gas booster pump

  • Stainless steel material cabinet

  • F.R.L combination for driven air (adjusts air pressure, add lubricating oil and water filter)

  • Driven air switch (Pump starting switch), driven air pressure gauge

  • Gas inlet switch, Gas inlet pressure gauge

  • Gas outlet switch, Gas outlet pressure gauge, unloading valve, interconnecting pipes etc.

  • And we could also customize it according to clients’special requirement.


Model

Pressure Ratio

Driven air pressure PL 

Formula to calculate outlet pressure

MAX Outlet
     Pressure(bar)*

Driven
     air inlet port

High pressure Outlet port

MAX Flow
     (L/min)**

DGS-DGG16

16:1

3-8 bar

16XPL

128

G 1/2

NPT/ZG

12.42

DGS-DGG28

28:1

3-8 bar

28XPL

224

G 1/2

NPT/ZG

7.11

DGS-DGGD166

16:1

3-8 bar

16XPL

128

G 1/2

NPT/ZG

19.73

DGS-DGGD28

28:1

3-8 bar

28XPL

224

G 1/2

NPT/ZG

11.30


DGS-CO2-B model liquid CO2(fire extinguisher) filling machine


specialsafety fire extinguisher refill station co2 for fire extinguisher-3
  • Main parameters:

  • The driving source: compressed air (by air compressor, need 3-8 bar air pressure)

  • Medium: CO2

  • Max output pressure: 12.8Mpa

  • Driven air inlet port: fast insert 12 per cent

  • Liquid CO2 inlet port: ZG3/8 internal thread

  • High pressure gas outlet port: ZG3/8 internal thread


Fire Extinguisher filling


specialsafety fire extinguisher refill station co2 for fire extinguisher-4
specialsafety fire extinguisher refill station co2 for fire extinguisher-5


video





A series of tests for Suncenter automatic liquid filling machine have been carried out. It has strictly tested in terms of the performance of the circuit board, plugs, voltage, housing, etc. The product has met the needs of low ripple without decreasing of the dynamic performance
Suncenter fire extinguisher refill station go through a polishing process once it is processed by CNC machines. It is gauged, calibrated and then polished to a perfect finish in a wide range of colors and designs. The product is easy to plug and easy to use
Suncenter automatic liquid filling machine has a good design. Its elements are programmed to respond to climatic factors, to improve energy efficiency or reduce solar heat, or for aesthetic reasons such as an art installation. The product has met the needs of low ripple without decreasing of the dynamic performance
The workmanship of Suncenter automatic liquid filling machine carefully conducted. It should go through timber cutting, tenoning, trepanning, pressing, or high-speed milling processes. Featuring the overcurrent and overvoltage protection function, the product is safe for use
The package of Suncenter fire extinguisher refill station will be done with professional materials. It is packaged with hardened carton, foam, cardboard, or wooden box to protect it in an all-around way to minimize transportation damage. The product can effectively provide the ultimate protection for the devices
fire extinguisher refill station is equipped with an advanced heat exchanger to greatly improve the heat exchange efficiency of the evaporator. Moreover, it has a variety of protection functions. It is of good durability and reliable safety.
Product Message
Chat Online 编辑模式下无法使用