loading

Become the first-class high pressure fluid control expert in the world

Suncenter  >  AI - Page Sitemap  >  Suncenter high-tech oxygen pump marketing for refrigeration industry
Suncenter high-tech oxygen pump marketing for refrigeration industry

Suncenter high-tech oxygen pump marketing for refrigeration industry

MOQ
1 Set
Brand Name
SUNCENTER
Certificate
ISO/CE/SGS
Warranty
13 Months
Packaging
By Plywood case
Shipping Port
Shenzhen/Hongkong
Payment
T/T,Western Union,Credit card.
Transaction method
EXW,FOB,DDP,CIF,CFR
Place of Origin
Guangdong Province, China (Mainland)
Delivery Time
Within 10-15 working days after received deposit
Price
Get Latest Price
Get the latest price
Quantity Needed:
Pieces
E-mail:
Company Advantages
1. oxygen pump is beautiful in appearance, compact in structure and easy in installation. Moreover, the noise reduction processing makes it low in noise during operation.
2. Dongguan Suncenter Fluid Control Equipment Co., Ltd provides all our customers with the services that they require under one roof. It has flexibility without the use of unloaders or bypass valves
3. Our professional quality control team and authoritative third parties have conducted a serious and rigorous review of product quality. The product has reliable performance and simple access to the operation
4. This product meets international industry quality standards. Its special design can effectively eliminate the dangers

Air driven refrigerant booster pump-SLM06


It's such a device that uses compressed air as power source, air driven refrigerant pump as pressure source and refrigerant as working medium, to get the corresponding high pressure value through regulating air drive pressure; and the ratio of output pressure to air drive pressure is 6:1.


When air drive pressure and outlet pressure reach balance, the refrigerant pump will stop pressurizing, and output pressure will be stable at the preset pressure, so it has such features: explosion-proof, output pressure adjustable, small volume, light weight, easy to operate, reliable performance, wide application range etc.  


Cool operation—No heat generated during liquid transfer. Minor warming during vapor transfer.


No refrigerant heating from the motor.


Safety—Pneumatically driven. Operates from air hose like an air tool. No electrical hazard.


Suncenter high-tech oxygen pump marketing for refrigeration industry-1
  • Air driven refrigerant booster pump-SLM06  


Driving air need

2-8bar

Pressure range

0-48bar

Pressure ratio

6:1

Flow rate

15L/min

Driving air size

ZG1/2

Increasing

63mm

Inlet size

ZG1/2

Stroke

60mm

Outlet size

ZG1/2

Noise

<75dB


DGS- SLM06 model refrigerant pump system


Suncenter high-tech oxygen pump marketing for refrigeration industry-2
  • The standard system including following parts:

  • SLM06 model refrigerant pump

  • Stainless steel frame cabinet

  • F.R.L combination for driven air (adjusts air pressure, add lubricating oil and water filter)

  • Driven air switch (Pump starting switch), driven air pressure gauge

  • Gas inlet switch, Gas inlet pressure gauge

  • Gas outlet switch, Gas outlet pressure gauge,  unloading valve, interconnecting pipes etc.

  • And we could also customize it according to clients’ special requirement.


DGS- SLM06 system = SLM06 booster pump+ following valves, gages, and parts


Suncenter high-tech oxygen pump marketing for refrigeration industry-3


DGS- SLM06 model refrigerant pump system with 16L Accumulator


Suncenter high-tech oxygen pump marketing for refrigeration industry-4
  • DGS- SLM06 model refrigerant pump system with 16L Accumulator


DGS-SLM06 model refrigerant pumps working picture


Suncenter high-tech oxygen pump marketing for refrigeration industry-5
Suncenter high-tech oxygen pump marketing for refrigeration industry-6



features

It's such a device that uses compressed air as power source, air driven refrigerant pump as pressure source and refrigerant as working medium, to get the corresponding high pressure value through  regulating air drive pressure; and the ratio of output pressure to air drive pressure is 6:1. When air drive pressure and outlet pressure reach balance, the refrigerant pump will stop pressurizing, and output pressure will be stable at the preset pressure, so it has such features: explosion-proof, output pressure adjustable, small volume, light weight, easy to operate, reliable performance, wide application range etc.  


  •   Cool operation—No heat generated during liquid transfer. Minor warming during vapor transfer.

  •   No refrigerant heating from the motor. 

  •   Safety—Pneumatically driven. Operates from air hose like an air tool. No electrical hazard. 


video





Company Features
1. Dongguan Suncenter Fluid Control Equipment Co., Ltd is a global leader in the oxygen pump industry. There are many experienced managing talents and professional technician with strong ability of refrigerant pump developing in Dongguan Suncenter Fluid Control Equipment Co., Ltd.
2. The quality of oxygen pump is assured by our professional technicians and mature technology crafts.
3. The oxygen pump is made to be of high quality which enjoys a high reputation. We have made philanthropy part of our company' growth plan. We encourage employees to take part in local volunteer grant programs, and regularly donating capitals for the non-profit organization.
The design of Suncenter freon pump can be really individualized, depending on what clients have specified that they want. Factors such as firmness and layers can be individually manufactured for each client. Any logos or brand information can be customized and printed on the item
Suncenter freon pump is a result of mechatronics. It is developed, designed, and manufactured on the basis of machine body, microelectronic device, sensor, and actuator technologies. Containing few detachable parts, this product saves much maintenance cost
Quality and safety analysis for Suncenter oxygen pump is stringently carried out. It is required to go through short circuit analysis, total load inspection, power analysis, insulation test, and electric arc resistant test. Any logos or brand information can be customized and printed on the item
Different inspection methods will be adopted on Suncenter refrigerant pump. Both its internal mechanical parts and external parts will be inspected by visual examination, radiographic inspection, or magnetic crack detection. It can be easily put in a corner without taking up too much space
Serious garment inspections are conducted on Suncenter refrigerant pump. This not only verifies that the product is free of unacceptable defects but also makes sure that all the necessary labels are in place according to the material used in the item. This product produces clear images or characters
The product is highly resistant to corrosion. Its metal parts are well coated to help it withstand rust, moisture, and chemical liquids. With an auto cutter, it simplifies the daily printing procedure
Product Message
Chat Online 编辑模式下无法使用
Leave Your Message inputting...