Become the first-class high pressure fluid control expert in the world

sales@chinasuncenter.com

Suncenter pump booster pump system for safety valve calibration-Suncenter-imgEnglish
Suncenter  > 

AI - Page Sitemap

 > 

Suncenter pump booster pump system for safety valve calibration

Suncenter pump booster pump system for safety valve calibration

Suncenter pump booster pump system for safety valve calibration

MOQ
1 Set
Brand Name
SUNCENTER
Certificate
ISO/CE/SGS
Warranty
13 Months
Packaging
By Plywood case
Shipping Port
Shenzhen/Hongkong
Payment
T/T,Western Union,Credit card.
Transaction method
EXW,FOB,DDP,CIF,CFR
Place of Origin
Guangdong Province, China (Mainland)
Delivery Time
Within 10-15 working days after received deposit
Price
Get Latest Price
Get the latest price
Quantity Needed:
Pieces
E-mail:

Compressed Air Driven Liquid Gas Booster Pump-DGG/DGGD Series


SUNCENTER pumps are air driven at a drive air pressure of 2 to 10bar (29 to145 psi) by the normal air compressor. Basically the principle of operation is similar to a reciprocating amplifier where control of the piston at the end position is regulated by a pilot operated 4/2 way valve.


Suncenter pumps feature a large air piston joint to a smaller diameter plunger. The pressure ratio is the difference of these two areas and is the method of determining maximum outlet pressure. Higher pressures obtained by using higher pressure ratios.Suncenter model numbers reflect the pumps nominal pressure ratios, while the technical data indicates exact ratios. The outlet pressure is easily to set through a simple air regulator. By multiplying the pressure ratio by the available shop air pressure, the nominal outlet pressure can be calculated.


Suncenter pump booster pump system for safety valve calibration-1



DGG Series Liquid Gas Booster Pumps


Suncenter pump booster pump system for safety valve calibration-2
  • DGG Series Liquid Gas Booster Pumps  


Model

Pressure  Boost Ratio

Driven air pressure PL 

Formula to calculate outlet pressure

MAX Outlet
     Pressure(bar)*

Liquid inlet Connection

Liquid outlet Connection

MAX Flow (L/min) 

DGG6

6:1

3-8 bar

6XPL

48

NPT1/2

NPT1/2

29.91

DGG10

10:1

3-8 bar

10XPL

80

NPT1/2

NPT1/2

18.84

DGG16

16:1

3-8 bar

16XPL

128

NPT1/2

NPT1/2

12.42

DGG28

28:1

3-8 bar

28XPL

224

NPT1/2

NPT1/2

7.11

DGG40

40:1

3-8 bar

40XPL

320

NPT1/2

NPT1/2

4.89

DGG64

64:1

3-8 bar

64XPL

512

NPT1/2

NPT3/8

3.08

DGG80

80:1

3-8 bar

80XPL

640

NPT1/2

NPT3/8

2.44

DGG100

100:1

3-8 bar

100XPL

800

NPT1/2

NPT3/8

1.92


DGGD Series Liquid Gas Pumps(Double acting)


Suncenter pump booster pump system for safety valve calibration-3
  • DGGD Series Liquid Gas Pumps(Double acting) 


Model

Pressure  Boost Ratio

Driven air pressure PL 

Formula to calculate outlet pressure

MAX Outlet
     Pressure(bar)*

Liquid inlet Connection

Liquid outlet Connection

MAX Flow (L/min)**

DGGD4

4:1

3-8 bar

4XPL

32

NPT1/2

NPT1/2

70.00

DGGD6

6:1

3-8 bar

6XPL

48

NPT1/2

NPT1/2

48.60

DGGD10

10:1

3-8 bar

10XPL

80

NPT1/2

NPT1/2

30.61

DGGD16

16:1

3-8 bar

16XPL

128

NPT1/2

NPT1/2

19.73

DGGD28

28:1

3-8 bar

28XPL

224

NPT1/2

NPT1/2

11.30

DGGD40

40:1

3-8 bar

40XPL

320

NPT1/2

NPT3/8

7.69

DGGD64

64:1

3-8 bar

64XPL

512

NPT1/2

NPT3/8

4.94

DGGD80

80:1

3-8 bar

80XPL

640

NPT1/2

NPT3/8

3.96

DGGD100

100:1

3-8 bar

100XPL

800

NPT1/2

NPT3/8

3.13



Suncenter DLS Series liquid gas filling booster pump system


SUNCENTER- Liquid gas filling pump systems are compact and delicacy solution tailored to customer specific requirements with air driven pumps as well as all accessories to be fitted and installed on the frame or in closed cabinet.


To operate this system, the pressure gauges, valves and pressure regulators have to be fitted on panels. The outlet pressure is easily to be set through a simple air regulator. The pump stops automatically when this end pressure is reached and restarts with a slight drop in the outlet pressure or an increase in the air drive pressure.


As the pressure will be generated by means of a pneumatically operated pump,the electric connection will not be necessary. To operate this system, the air driven pump have to be equipped with the air control unit combined filter, pressure-regulating valve, pressure control gauge as well as manual relieve valve. In this operation, the pump will be mounted to the stainless steel tank in the closed cabinet in a compact and space saving manner. Pressure gauges, valves and pressure regulators will be fitted on panel.


Suncenter pump booster pump system for safety valve calibration-4


DLS liquid gas booster system = liquid gas booster pump+ following valves, gages, and parts



Suncenter pump booster pump system for safety valve calibration-5


The hottest selling- Model C cabinet picture


Suncenter pump booster pump system for safety valve calibration-6
  • The standard gas booster pumps system including following parts:

  • Air –driven liquid N2O/CO2/NOVEC/Refrigerant gas booster pump

  • Stainless steel (carbon steel) material cabinet

  • F.R.L combination for driven air (adjusts air pressure, add lubricating oil and water filter)

  • Driven air switch (Pump starting switch), driven air pressure gauge

  • Gas inlet switch, Gas inlet pressure gauge

  • Gas outlet switch, Gas outlet pressure gauge, unloading valve, interconnecting pipes etc.

  • And we could also customize it according to clients’ special requirement.


Model

Pressure Ratio

Driven air pressure PL 

Formula to calculate outlet pressure

MAX Outlet
     Pressure(bar)*

Driven
     air inlet    port

High pressure Outlet port

MAX Flow
     (L/min)**

DLS-DGG6

6:1

3-8 bar

6XPL

48

G 1/2

NPT/ZG

29.91

DLS-DGG10

10:1

3-8 bar

10XPL

80

G 1/2

NPT/ZG

18.84

DLS-DGG16

16:1

3-8 bar

16XPL

128

G 1/2

NPT/ZG

12.42

DLS-DGG28

28:1

3-8 bar

28XPL

224

G 1/2

NPT/ZG

7.11

DLS-DGG40

40:1

3-8 bar

40XPL

320

G 1/2

NPT/ZG

4.89

DLS-DGG64

64:1

3-8 bar

64XPL

512

G 1/2

NPT/ZG

3.08

DLS-DGG80

80:1

3-8 bar

80XPL

640

G 1/2

NPT/ZG

2.44

DLS-DGG100

100:1

3-8 bar

100XPL

800

G 1/2

NPT/ZG

1.92


DLS-DGGD series Liquid gas booster system technical specification


Model

Pressure Ratio

Driven air pressure PL 

Formula to calculate outlet pressure

MAX Outlet
     Pressure(bar)*

Driven
     air inlet    port

High pressure Outlet port

MAX Flow
     (L/min)**

DLS-DGGD4

4:1

3-8 bar

4XPL

32

G 1/2

NPT/ZG

70.00

DLS-DGGD6

6:1

3-8 bar

6XPL

48

G 1/2

NPT/ZG

48.60

DLS-DGGD10

10:1

3-8 bar

10XPL

80

G 1/2

NPT/ZG

30.61

DLS-DGGD16

16:1

3-8 bar

16XPL

128

G 1/2

NPT/ZG

19.73

DLS-DGGD28

28:1

3-8 bar

28XPL

224

G 1/2

NPT/ZG

11.30

DLS-DGGD40

40:1

3-8 bar

40XPL

320

G 1/2

NPT/ZG

7.69

DLS-DGGD64

64:1

3-8 bar

64XPL

512

G 1/2

NPT/ZG

4.94

DLS-DGGD80

80:1

3-8 bar

80XPL

640

G 1/2

NPT/ZG

3.96

DLS-DGGD100

100:1

3-8 bar

100XPL

800

G 1/2

NPT/ZG

3.13



features

  •   Compressed Air driven - no electricity required (connect to normal air compressor)

  •   In order to extend the lifetime of the pump, the driving air pressure should not be higher than 8 bar

  •   No airline lubricator required

  •   Wide range of models with different ratios

  •   Built-in-cooling on most models

  •   Easy to install, operate and maintain

  •   Best price / performance ratio

  •   No heat, flame or spark risk and explosion proof

  •   Automatic pressure holding, whatever the cause of the pressure drop, the Suncenter booster pump will automatically start, keep the loop pressure constant

  •   Applicable for various kinds of gas such as N2O/CO2/NOVEC/Refrigerant etc.

  •   For liquid gas(liquid+gas mixture) cylinder transfer/filling/recovery

  •  For CO2 Fire Extinguisher filling 

  •   For Supercritical CO2 extraction


video





[17] has good quality. It is guaranteed by examining the plastics and additives, glass, coating and frame material inspection procedures.
During the development stage of Suncenter high pressure booster pump, possible electric issues will be considered, including the electric strength, electric heating elements, the nominal voltage, and power source type.
According to different requirements of customers, the process used to manufacture Suncenter booster pump system is not the same, mainly including ordinary weaving, washing, dyeing, iron removal and so on.
The quality of Suncenter booster pump system is guaranteed. It has undergone comprehensive testing, including verifying appliance characteristics, measuring energy efficiency and energy consumption, energy class labeling and assuring electrical safety.
Suncenter high pressure booster pump is professionally designed. It is created by our product designers who are proficient in design concepts and principles of design, aesthetics, basic styles, and bedding styling and detail.
It is absolute that the quality of this product is assured by professional quality check staff.
Our commitment to quality ensures that the product is always at the best quality.
With superior craftsmanship, Suncenter ensures the quality of this product.
The QC team adopts professional quality standards to ensure the quality of this product.
Our strict quality management system ensures the high quality of the product.
The product, as it is manufactured by ourselves, is assured to meet international quality standards.
The use of this product in commercial building designs will become an enduring trend for many aesthetic and energy efficiency reasons.
This mattress can provide some relief for health issues like arthritis, fibromyalgia, rheumatism, sciatica, and tingling of the hands and feet.
Excellent performance makes this product ideal for use with all types of projectors, particularly with the increasing demands of high definition material.
The product consumes very little energy, hence, the solar power stored in its battery can be used for many hours.
This product with energy rating labels is able to provide consumers with information on the energy-efficiency, allowing them to estimate their annual energy use and costs.
The product has revolutionized the method of production, increase productivity, and cut production costs, which eventually promotes economic growth.
Product Message
Chat Online inputting...