loading

Become the first-class high pressure fluid control expert in the world

Suncenter  >  AI - Page Sitemap  >  Suncenter safe gas booster free design for safety valve calibration
Suncenter safe gas booster free design for safety valve calibration

Suncenter safe gas booster free design for safety valve calibration

MOQ
1 Set
Brand Name
SUNCENTER
Certificate
ISO/CE/SGS
Warranty
13 Months
Packaging
By Plywood case
Shipping Port
Shenzhen/Hongkong
Payment
T/T,Western Union,Credit card.
Transaction method
EXW,FOB,DDP,CIF,CFR
Place of Origin
Guangdong Province, China (Mainland)
Delivery Time
Within 10-15 working days after received deposit
Price
Get Latest Price
Get the latest price
Quantity Needed:
Pieces
E-mail:

Compressed Air Driven Gas Booster Pump- DGA/DGD/DGT Series


Suncenter Air Driven Gas Boosters provide for pressures up to 80Mpa (11,600 psi). Used for virtually all known gases, these boosters are ideal for increasing gas pressure, transferring high pressure gas, charging cylinders and scavenging. Key features include:


Applications for Air Driven Gas Boosters


SUNCENTER Air Driven Gas Boosters provide for pressures up to 80Mpa. Used for oil free compression not only of air or Nitrogen, but also flammable and risk gases like hydrogen, oxygen and natural gas. These boosters are ideal for increasing gas pressure, transferring high pressure gas, charging cylinders and scavenging.


Air driven boosters are an efficient alternative instead of electrically driven products and can be used in explosion- proof areas.


As a result of the wide range of models it is possible to select the optimum booster for each application. Single stage, double acting or two stage boosters or a combination of these models can be used to achieve different operating pressures and flow capacities.


SUNCENTER Air Driven Gas Boosters are ideal and widely used for hydrostatic and burst testing for valves, pipes, tubing and pressure vessels; Calibration for safety valves; Automobile regulator detecting and telecommunication cable inflatable appliances.


Suncenter safe gas booster free design for safety valve calibration-1



DGA series gas booster pumps(Single acting, single air drive head):  


Suncenter safe gas booster free design for safety valve calibration-2
  • DGA pumps are available with high quality seals, which provide significantly better service life as well. Pump head fitted with exhaust cooling devices. All parts in contact with the gas are made of stainless steel.


Model

Pressure boost ratio

Min. gas Inlet pressure PA (bar)

Max.gas Inlet pressure PA (bar)

Max. gas outlet 

pressure PB (bar)

 Driven air pressure  PL

Formula to
 calculate gas outlet pressure PB

Connection: Gas Inlet /
Gas outlet (NPT thread)

Max. flow at driven air pressure of 6bar (L/min)

DGA02

2:1

1.0

16

16

2bar-8 bar

2X PL

1/2 / 1/2

960 (at PA of 6 bar )

DGA05

5:1

0

40

40

2bar-8 bar

5XPL

1/2 / 1/2

680(at PA of 6 bar )

DGA06

6:1

2.0

48

48

2bar-8 bar

6XPL

1/2 / 1/2

360(at PA of 10 bar )

DGA10

10:1

3.5

80

80

2bar-8 bar

10XPL

3/8/ 3/8

210(at PA of 10 bar )

GA15

15:1

3.5

120

120

2bar-8 bar

15XPL

3/8/ 3/8

190(at PA of 10 bar )

DGA25

25:1

7.0

200

200

2bar-8 bar

25XPL

1/4/ 1/4

120(at PA of 20 bar )

DGA40

40:1

10

320

320

2bar-8 bar

40XPL

1/4/ 1/4

200(at PA of 40 bar )

DGA60

60:1

20 

480

480

2bar-8 bar

60XPL

1/4/ 1/4

180(at PA of 40 bar )

DGA100

100:1

25

800

800

2bar-8 bar

100XPL

1/4/ M14X1.5

136(at PA of 40 bar )


DGD series gas booster pumps(Double acting ):


Suncenter safe gas booster free design for safety valve calibration-3
  • DGD series pumps are double acting, with single air driven heads type.   

  • DGD pumps are available with high quality seals, which provide significantly better service life

  • Double pump heads with exhaust cooling devices. 

  • All components in contact with the gas are made of stainless steel. 

  • Pipes mounting way are available as customized.


Model

Pressure boost ratio

Min. gas Inlet 

pressure PA (bar)

Max.gas Inlet 

pressure PA (bar)

Max. gas outlet 

pressure PB (bar)

 Driven air pressure PL

Formula to
calculate gas outlet pressure PB

Connection: Gas Inlet / Gas outlet (NPT thread)

Max. flow at driven air pressure of 6bar (L/min)

DGD10

10:1

3.5

80

80

2bar-8 bar

10XPL+ PA

3/8/3/8

410(at PA of 6 bar )

DGD15

15:1

5

120

120

2bar-8 bar

15XPL+ PA

3/8/3/8

350 (at PA of 6 bar )

DGD25

25:1

10

200

200

2bar-8 bar

25XPL+ PA

1/4/1/4

396(at PA of 20 bar )

DGD40

40:1

15

320

320

2bar-8 bar

40XPL+ PA

1/4/1/4

320(at PA of 40 bar )

DGD60

60:1

25

480

480

2bar-8 bar

60XPL+ PA

1/4/1/4

215(at PA of 40 bar )

DGD100

100:1

35

800

800

2bar-8 bar

100XPL+ PA

1/4/M14*1.5

300(at PA of 60 bar )

DGD130

130:1

50 

1040

1040 

2bar-8 bar

130XPL+ PA

1/4/M14*1.5

180(at PA of 60 bar )


DGT series gas booster pumps(Double acting, double stage, single air drive head ):


Suncenter safe gas booster free design for safety valve calibration-4
  • DGT pumps are double acting, double stage with single air drive head pumps. They can provide for super high pressure with very low inlet pressure.

  • DGT pumps are available with high quality seals, which provide significantly better service life

  • All parts in contact with the gas are made of stainless steel.


Model

Pressure boost ratio

Min. gas Inlet 

pressure PA (bar)

Max.gas Inlet 

pressure PA (bar)

Max. gas outlet 

pressure PB (bar)

 Driven air pressure  

PL

Formula to calculate gas outlet pressure PB

Connection: Gas Inlet /
     Gas outlet (NPT thread)

Max. flow at driven air pressure of 6bar (L/min)

DGT15

15:1

0.1

56

120

2-8 bar

15XPL

3/8/ 1/4

230(at PA of 8 bar )

DGT25

25:1

0.1

10

200

2-8 bar

25XPL

3/8/ 1/4

156(at PA of 8 bar )

DGT7/25

25:1

5

56

200

2-8 bar

25XPL

3/8/ 1/4

156(at PA of 8 bar )

DGT40

40:1

0.1

10

320

2-8 bar

40XPL

3/8/ 1/4

124(at PA of 8 bar )

DGT15/40

40:1

5

120

320

2-8 bar

40XPL

3/8/ 1/4

124(at PA of 8 bar )

DGT60

60:1

0.1

10

480

2-8 bar

60XPL

3/8/ 1/4

80(at PA of 15 bar )

DGT15/60

60:1

6

120

480

2-8 bar

60XPL

3/8/ 1/4

80(at PA of 15 bar )

DGT100

100:1

0.1

10

800

2-8 bar

100XPL

3/8/ 1/4

63(at PA of 8 bar )



Suncenter safe gas booster free design for safety valve calibration-5
  • DGT series gas booster working picture 


Suncenter safe gas booster free design for safety valve calibration-6


         Gas pressure booster for cylinder transfer and filling
Suncenter safe gas booster free design for safety valve calibration-7


         DGS series gas booster system working picture



features

  •   Compressed Air driven - no electricity required (connect to normal air compressor)  

  •   In order to extend the lifetime of the pump, the driving air pressure should not be higher than 8 bar

  •   No airline lubricator required

  •   Hydrocarbon free - separation between air and gas sections

  •    Pressures to 80Mpa (11,600 psi)

  •    Wide range of models with different ratios

  •   Built-in-cooling on most models

  •   Easy to install, operate and maintain

  •   Best price / performance ratio

  •   No heat, flame or spark risk and explosion proof 

  •   Automatic pressure holding, whatever the cause of the pressure drop, the Suncenter   pump will automatically start, keep the loop pressure constant 

  •   Applicable gas:Air/Ar(Argon)/He(Helium)/H2(Hydrogen)/O2(Oxygen)N2(Nitrogen) CO2/NO2/CH4/C2H2/LNG/LPG/CNG/FM200/SF6/H2S etc


video





automatic booster pump The workmanship is fine, the materials are exquisite, the design is scientific, the structure is reasonable, and before leaving the factory, there will be special quality inspection personnel to test, so the quality is guaranteed.
Dongguan Suncenter Fluid Control Equipment Co., Ltd Not only has a complete procurement management system and a rigorous quality control system, but also has mastered various advanced production techniques, and is able to produce automatic booster pump with excellent quality.
Dongguan Suncenter Fluid Control Equipment Co., Ltd has been operating in good faith for many years, and has accumulated rich industry experience in product development and manufacturing. The gas booster produced can meet the national CCC certification standards in terms of quality and performance.
Dongguan Suncenter Fluid Control Equipment Co., Ltd The pursuit of excellence, adhere to the use of advanced concepts, high-quality materials and exquisite craftsmanship automatic booster pump, effectively guarantee the rationality of the structure automatic booster pump and the stability of performance, the quality is trustworthy.
We not only have an independent production workshop, advanced production equipment, professional production personnel and multiple automated production lines, but also have established a set of scientific and rigorous quality control system to ensure that the gas booster produced are of high quality.
In addition to quality that meets industry standards, this product has a longer life than other products. The product effectively displays promotional messages for items
Product Message
Chat Online 编辑模式下无法使用
Leave Your Message inputting...