Become the first-class high pressure fluid control expert in the world

sales@chinasuncenter.com

English
Suncenter  >  AI - Page Sitemap  >  energy saving nitrogen pumps pressure from manufacturer for natural gas boosts pressure
energy saving nitrogen pumps pressure from manufacturer for natural gas boosts pressure

energy saving nitrogen pumps pressure from manufacturer for natural gas boosts pressure
  • energy saving nitrogen pumps pressure from manufacturer for natural gas boosts pressure
  • energy saving nitrogen pumps pressure from manufacturer for natural gas boosts pressure
  • energy saving nitrogen pumps pressure from manufacturer for natural gas boosts pressure
  • energy saving nitrogen pumps pressure from manufacturer for natural gas boosts pressure

energy saving nitrogen pumps pressure from manufacturer for natural gas boosts pressure

Gas booster pressure test benchSuncenter - Air/Gas pressure test bench are compact and delicacy solution...
Get the latest price
Quantity Needed:
Pieces
E-mail:
Enterprise Strength
  • Suncenter Fluid Control Equipment always sticks to the tenet that we serve customers wholeheartedly and promotes the healthy and optimistic brand culture. We are committed to providing professional and comprehensive services.
Product Comparison
Suncenter Fluid Control Equipment guarantees gas booster to be high-quality by carrying out highly standardized production. Compared with other products in the same category, it has the following advantages.
Company Advantages
1. The electric performance test of Suncenter air pressure testing is conducted at the quality inspection stage. The main electrical performance index such as capacity, internal resistance, lifespan, and short circuit protection will be tested by the QC team.
2. Our professional technicians monitor the quality of products throughout the production process, which greatly ensures the quality of products.
3. This piece of furniture can add refinement and reflect the image people have in their minds of the way they want each space to look, feel and function.
4. This product significantly helps release unnecessary impact and stress on parts of people's feet and knees by providing enough stability.

Gas booster pressure test bench


Suncenter - Air/Gas pressure test bench are compact and delicacy solution tailored to customer specific requirements with gas(air) boosters as well as all accessories to be fitted and installed in the frame or a closed cabinet.


To operate this system, the pressure gauges, valves and pressure regulators have to be fitted on panels. The outlet pressure is easily to be set through a simple air regulator.


The pump stops automatically when this end pressure is reached and restarts with a slight drop in the outlet pressure or an increase in the air drive pressure.


Operating pressure up to 80 MPa, for higher pressure, pump with double driven heads is an ideal option.


energy saving nitrogen pumps pressure from manufacturer for natural gas boosts pressure-1



The hottest selling- Model C frame type cabinet picture


energy saving nitrogen pumps pressure from manufacturer for natural gas boosts pressure-2
  • The standard gas booster pumps system including following parts:

  • Air –driven gas booster pump (DGA/DGD/DGT three series for choosing)

  • Stainless steel (carbon steel) material cabinet (Three models for choosing)

  • F.R.L combination for driven air (adjusts air pressure, add lubricating oil and water filter)

  • Driven air switch (Pump starting switch), driven air pressure gauge

  • Gas inlet switch, Gas inlet pressure gauge

  • Gas outlet switch, Gas outlet pressure gauge,  unloading valve, interconnecting pipes etc.

  • And we could also customize it according to clients’ special requirement.


energy saving nitrogen pumps pressure from manufacturer for natural gas boosts pressure-3
  • DGS series air/gas pressure test bench with round chart recorder


Model

Pressure boost ratio

Min. gas
Inlet pressure
PA (bar)

Max.gas
Inlet pressure
PA (bar)

Max. gas
outlet pressure PB (bar)

 Driven air pressure  PL

Formula to
calculate gas outlet pressure PB

Connection:
Gas Inlet /
Gas outlet (ZG thread)

Max. flow at driven air pressure of 6bar (L/min)

DGS-DGA02

2:1

1.0

16

16

2-8 bar

2X PL

1/2 / 1/2

960 (at PA of 6 bar )

DGS-DGA05

5:1

0

40

40

2-8 bar

5XPL

1/2 / 1/2

680(at PA of 6 bar )

DGS-DGA10

10:1

3.5

80

80

2-8 bar

10XPL

3/8/ 3/8

210(at PA of 10 bar )

DGS-DGA25

25:1

7.0

200

200

2-8 bar

25XPL

1/4/ 1/4

120(at PA of 20 bar )

DGS-DGA40

40:1

10

320

320

2-8 bar

40XPL

1/4/ 1/4

200(at PA of 40 bar )

DGS-DGA60

60:1

20

480

480

2-8 bar

60XPL

1/4/ 1/4

180(at PA of 40 bar )

DGS-DGA100

100:1

25

800

800

2-8 bar

100XPL

1/4/ M14X1.5

136(at PA of 40 bar )

DGS-DGA130

130:1

35

800

1040

2-8 bar

130XPL

1/4/ M14X1.5

120(at PA of 40 bar )


Technical specification for DGS-DGD series


Model

Pressure boost ratio

Min. gas
Inlet pressure
PA (bar)

Max.gas
Inlet pressure
PA (bar)

Max. gas 

outlet pressure PB (bar)

 Driven air pressure  PL

Formula to
calculate gas outlet pressure PB

Connection:
Gas Inlet /
Gas outlet (ZG thread)

Max. flow at driven air pressure of 6bar (L/min)

DGS-DGD10

10:1

3.5

80

80

2-8 bar

10XPL+ PA

3/8/3/8

410(at PA of 6 bar )

DGS-DGD25

25:1

10

200

200

2-8 bar

25XPL+ PA

1/4/1/4

396(at PA of 20 bar )

DGS-DGD40

40:1

15

320

320

2-8 bar

40XPL+ PA

1/4/1/4

320(at PA of 40 bar )

DGS-DGD60

60:1

25

480

480

2-8 bar

60XPL+ PA

1/4/1/4

215(at PA of 40 bar )

DGS-DGD100

100:1

35

800

800

2-8 bar

100XPL+ PA

1/4/M14*1.5

300(at PA of 60 bar )


Technical specification for DGS-DGT series


Model

Pressure boost ratio

Min. gas
Inlet pressure
PA (bar)

Max.gas
Inlet pressure
PA (bar)

Max. gas
outlet pressure PB (bar)

 Driven air pressure  PL

Formula to
calculate gas outlet pressure PB

Connection:
Gas Inlet /
Gas outlet (ZG thread)

Max. flow at driven air pressure of 6bar (L/min)

DGS-DGT25

25:1

0.1

10

200

 2-8 bar

25XPL+3.5XPA

1/4/ 1/4

136(at PA of 8 bar )

DGS-DGT40

40:1

0.1

10

320

2-8 bar

40XPL+ 6XPA

 1/4/1/4

124(at PA of 8 bar )

 DGS-DGT10/60

10:1/60:1

0.1

10

480

2-8 bar

60XPL+6X PA

 1/4/1/4

84(at PA of 8 bar )

DGS-DGT25/60

25:1/60:1

10

25

480

2-8 bar

60XPL+2.5XPA

 1/4/1/4

80(at PA of 15 bar )

DGS-DGT100

100:1

0.1

10

800

2-8 bar

100XPL+10XPA

1/4/ M14*1.5

63(at PA of 8 bar )


video





Company Features
1. It takes a lot of efforts for Suncenter to be the leading nitrogen pumps supplier.
2. We have a team of talented engineers and craftsmen. They are committed to the quality of our products and are always seeking ways to improve the quality of our products.
3. Throughout the production process, we keep on pursuing an eco-friendly and sustainable approach. We will make our product more sustainable by adopting new raw materials or extending their life cycles. We will bring a customer-centric mindset to every team. We will set up a specific customer service team to be solely responsible for monitoring customer satisfaction during the whole process and offer customers timely responses.
Suncenter air pressure testing has been verified by passing various on-site tests. They cover fitting testing, seam strength testing, dry & wet crocking testing, fatigue testing, etc. The product enjoys popularity in North America, Europe, AU, and Japan
Suncenter air pressure testing must go through these following production stages, including metal materials procurement and preparation, components machining, surface polishing, and assembly. It is especially helpful for finding the lost key or something that has fallen under the car seat, and for exploring caves
A core series of tests are performed on Suncenter air pressure testing. They are colorfastness testing, dimensional stability testing, fabric weight testing, flammability testing, etc. The batteries of the product feature short circuit protection
Suncenter air pressure testing has a unique design. Our designers experiment with various materials, often mixing textures, textiles or even incorporating multimedia elements into its design. Using this product at night significantly reduces the likelihood of accidents
During the design of Suncenter nitrogen pumps, some crucial elements have been considered, such as stress distribution, biomechanical about foot development, comfort and cushion level to the feet, etc. It is especially helpful for finding the lost key or something that has fallen under the car seat, and for exploring caves
This product is resistant to high temperatures. It is made of a heat-resistanting material with a high melting and high decomposition point. It is designed in an enclosed structure, preventing any dust or insects from entering into it
Product Message
Chat Online inputting...