Become the first-class high pressure fluid control expert in the world

Home  >  Best PRODUCTS  >  Best High Pressure Booster System For sell  >  Fire extinguisher filling machine Wholesale  > 

filling automatic liquid filling machine factory price for fire extinguisher Suncenter

filling automatic liquid filling machine factory price for fire extinguisher Suncenter

filling automatic liquid filling machine factory price for fire extinguisher Suncenter
  • filling automatic liquid filling machine factory price for fire extinguisher Suncenter
  • filling automatic liquid filling machine factory price for fire extinguisher Suncenter
  • filling automatic liquid filling machine factory price for fire extinguisher Suncenter
  • filling automatic liquid filling machine factory price for fire extinguisher Suncenter
  • filling automatic liquid filling machine factory price for fire extinguisher Suncenter
  • filling automatic liquid filling machine factory price for fire extinguisher Suncenter

filling automatic liquid filling machine factory price for fire extinguisher Suncenter

MOQ
1 Set
Brand Name
SUNCENTER
Certificate
ISO/CE/SGS
Warranty
13 Months
Packaging
By Plywood case
Shipping Port
Shenzhen/Hongkong
Payment
T/T,Western Union,Credit card.
Transaction method
EXW,FOB,DDP,CIF,CFR
Place of Origin
Guangdong Province, China (Mainland)
Delivery Time
Within 10-15 working days after received deposit
Price
Get Latest Price
Get the latest price
Quantity Needed:
Pieces
E-mail:
Enterprise Strength
  • With a focus on service, Suncenter Fluid Control Equipment improves services by constantly innovating service management. This specifically reflects in the establishment and improvement of the service system, including pre-sales, in-sales, and after-sales.
Application Scope
With wide application, hydro test pump can be used in the following aspects.While providing quality products, Suncenter Fluid Control Equipment is dedicated to providing personalized solutions for customers according to their needs and actual situations.
  • Suncenter-automatic filling machine ,automatic liquid filling machine | Suncenter
Company Advantages
1. Suncenter automatic liquid filling machine is designed utilizing advanced production technology in line with industry norms.
2. automatic liquid filling machine that has been developed by our professional team offers great supports for the operation of automatic filling machine .
3. It is established that automatic filling machine has a long service life and possesses other features like automatic liquid filling machine .
4. Dongguan Suncenter Fluid Control Equipment Co., Ltd provides excellent customer service internally and externally.

DGS-FM-5A model automatic FM200 filling machine


Solution A (DGS-FM-5A) added the sensors, electromagnetic valve, vacuum pump, and the electronic scale based on solution B (manual control),it is automatic control mode


Suncenter-High-quality Fire Extinguisher Refill Station | Co2 Fire Extinguisher
  • Main parameters:

  • The driving source: compressed air (by air compressor, need 3-8 bar air pressure)

  • Medium: FM200/ NOVEC/Nitrogen

  • Boost ratio: 5:1

  • Output pressure: 4.2 Mpa/5.3Mpa

  • Driven air inlet port: fast insert 12 per cent

  • Nitrogen/FM200 inlet port: ZG3/8 internal thread

  • High pressure gas outlet port: ZG3/8 internal thread

  • Electric scale range:0-500kg(there is also max 1000kg for optional)


DGS-DGGD16 model liquid CO2 filling equipment


Suncenter-High-quality Fire Extinguisher Refill Station | Co2 Fire Extinguisher-1
  • The CO2 Fire Extinguisher filling equipment including following parts:

  • Air–driven liquid CO2 gas booster pump

  • Stainless steel material cabinet

  • F.R.L combination for driven air (adjusts air pressure, add lubricating oil and water filter)

  • Driven air switch (Pump starting switch), driven air pressure gauge

  • Gas inlet switch, Gas inlet pressure gauge

  • Gas outlet switch, Gas outlet pressure gauge, unloading valve, interconnecting pipes etc.

  • And we could also customize it according to clients’special requirement.


Model

Pressure Ratio

Driven air pressure PL 

Formula to calculate outlet pressure

MAX Outlet
     Pressure(bar)*

Driven
     air inlet port

High pressure Outlet port

MAX Flow
     (L/min)**

DGS-DGG16

16:1

3-8 bar

16XPL

128

G 1/2

NPT/ZG

12.42

DGS-DGG28

28:1

3-8 bar

28XPL

224

G 1/2

NPT/ZG

7.11

DGS-DGGD166

16:1

3-8 bar

16XPL

128

G 1/2

NPT/ZG

19.73

DGS-DGGD28

28:1

3-8 bar

28XPL

224

G 1/2

NPT/ZG

11.30


DGS-CO2-B model liquid CO2(fire extinguisher) filling machine


Suncenter-High-quality Fire Extinguisher Refill Station | Co2 Fire Extinguisher-2
  • Main parameters:

  • The driving source: compressed air (by air compressor, need 3-8 bar air pressure)

  • Medium: CO2

  • Max output pressure: 12.8Mpa

  • Driven air inlet port: fast insert 12 per cent

  • Liquid CO2 inlet port: ZG3/8 internal thread

  • High pressure gas outlet port: ZG3/8 internal thread


Fire Extinguisher filling


Suncenter-High-quality Fire Extinguisher Refill Station | Co2 Fire Extinguisher-3
Suncenter-High-quality Fire Extinguisher Refill Station | Co2 Fire Extinguisher-4


video





Company Features
1. Dongguan Suncenter Fluid Control Equipment Co., Ltd has gained wide popularity for its automatic filling machine .
2. Dongguan Suncenter Fluid Control Equipment Co., Ltd introduces overseas advanced equipment and technology cores.
3. We are committed to encouraging more sustainable practices for both our customers and our suppliers, and to drive sustainability through the supply chain. Hard-working, Efficient, Rigorous, Premium is always regarded as our working principle. We devote to increase productivity to manufacture products with superior quality. Ask online!
Favorable rate
100%
Buyer impression
This product has no buyer impression
  • All reviews(0)
  • Praise (0)
  • Average (0)
  • Bad review (0)
Product Message
社媒暂无评论
Chat Online 编辑模式下无法使用
Leave Your Message inputting...