loading

Become the first-class high pressure fluid control expert in the world

Suncenter  >  AI - Page Sitemap  >  SLM06 model Refrigerant pump
SLM06 model Refrigerant pump

SLM06 model Refrigerant pump

MOQ
1 Set
Brand Name
SUNCENTER
Certificate
ISO/CE/SGS
Warranty
13 Months
Packaging
By Plywood case
Shipping Port
Shenzhen/Hongkong
Payment
T/T,Western Union,Credit card.
Transaction method
EXW,FOB,DDP,CIF,CFR
Place of Origin
Guangdong Province, China (Mainland)
Delivery Time
Within 10-15 working days after received deposit
Price
Get Latest Price
Get the latest price
Quantity Needed:
Pieces
E-mail:
Product Comparison
Compared with other products in the same category, gas booster has the following competitive advantages.
  • Suncenter-SLM06 model Refrigerant pump
    Suncenter-SLM06 model Refrigerant pump-1
Application Scope
The hydro test pump produced by Suncenter Fluid Control Equipment has a wide range of applications.While providing quality products, Suncenter Fluid Control Equipment is dedicated to providing personalized solutions for customers according to their needs and actual situations.
  • Suncenter-SLM06 model Refrigerant pump-2
Company Advantages
1. Suncenter refrigerant pump is delicately manufactured by combining the best materials and the lean production method.
2. The product has the advantage of strong compatibility. It can perfectly work with other mechanical systems to bring out the best results.
3. The product stands out for its stable operation. Since it is mainly controlled by microcomputers, it can run stably without any break.
4. The use of this product means saving time and labor costs. Thanks to its high efficiency, it can quickly finish tasks that people can not do.
5. This product will finally contribute to the improvement in production efficiency. Because it can effectively eliminate human error during operation.

Air driven refrigerant booster pump-SLM06


It's such a device that uses compressed air as power source, air driven refrigerant pump as pressure source and refrigerant as working medium, to get the corresponding high pressure value through regulating air drive pressure; and the ratio of output pressure to air drive pressure is 6:1.


When air drive pressure and outlet pressure reach balance, the refrigerant pump will stop pressurizing, and output pressure will be stable at the preset pressure, so it has such features: explosion-proof, output pressure adjustable, small volume, light weight, easy to operate, reliable performance, wide application range etc.  


Cool operation—No heat generated during liquid transfer. Minor warming during vapor transfer.


No refrigerant heating from the motor.


Safety—Pneumatically driven. Operates from air hose like an air tool. No electrical hazard.


SLM06 model Refrigerant pump-1
  • Air driven refrigerant booster pump-SLM06  


Driving air need

2-8bar

Pressure range

0-48bar

Pressure ratio

6:1

Flow rate

15L/min

Driving air size

ZG1/2

Increasing

63mm

Inlet size

ZG1/2

Stroke

60mm

Outlet size

ZG1/2

Noise

<75dB


DGS- SLM06 model refrigerant pump system


SLM06 model Refrigerant pump-2
  • The standard system including following parts:

  • SLM06 model refrigerant pump

  • Stainless steel frame cabinet

  • F.R.L combination for driven air (adjusts air pressure, add lubricating oil and water filter)

  • Driven air switch (Pump starting switch), driven air pressure gauge

  • Gas inlet switch, Gas inlet pressure gauge

  • Gas outlet switch, Gas outlet pressure gauge,  unloading valve, interconnecting pipes etc.

  • And we could also customize it according to clients’ special requirement.


DGS- SLM06 system = SLM06 booster pump+ following valves, gages, and parts


SLM06 model Refrigerant pump-3


DGS- SLM06 model refrigerant pump system with 16L Accumulator


SLM06 model Refrigerant pump-4
  • DGS- SLM06 model refrigerant pump system with 16L Accumulator


DGS-SLM06 model refrigerant pumps working picture


SLM06 model Refrigerant pump-5
SLM06 model Refrigerant pump-6



features

It's such a device that uses compressed air as power source, air driven refrigerant pump as pressure source and refrigerant as working medium, to get the corresponding high pressure value through  regulating air drive pressure; and the ratio of output pressure to air drive pressure is 6:1. When air drive pressure and outlet pressure reach balance, the refrigerant pump will stop pressurizing, and output pressure will be stable at the preset pressure, so it has such features: explosion-proof, output pressure adjustable, small volume, light weight, easy to operate, reliable performance, wide application range etc.  


  •   Cool operation—No heat generated during liquid transfer. Minor warming during vapor transfer.

  •   No refrigerant heating from the motor. 

  •   Safety—Pneumatically driven. Operates from air hose like an air tool. No electrical hazard. 


video





Company Features
1. Dongguan Suncenter Fluid Control Equipment Co., Ltd is skilled at the research and development and manufacture of refrigerant pump.
2. Our technology takes the lead in the industry of oxygen pump .
3. We implement the Sustainability Policy. In addition to complying with existing environmental laws and regulations, we practice a forward-looking environmental policy that encourages responsible and prudent use of all resources throughout the manufacture. Check now! We consider that we have the responsibility to protect our environment. During our production processes, we consciously minimize our impact on the environment. For example, we have introduced special wastewater treating facilities to prevent polluted water from flowing into seas or rivers.
The series of freon pump are refrigerant pump, will bring the best result of refrigerant pump for you.
freon pump adopt refrigerant pump materials, generate features such as refrigerant pump.
refrigerant pump are likely to possess features likerefrigerant pump.
freon pump is designed as freon pump and provides freon pump solution.
The production of oxygen pump always takes freon pump into account.
The product has easy maintainance access. It is designed for accessibility for maintenance, complying with OSHA standards CFR 1910.66, CFR 1910.28 and ANSI/IWCA I-14.1 'Window Cleaning Safety Standard.'
Product Message
Chat Online 编辑模式下无法使用
Leave Your Message inputting...