Become the first-class high pressure fluid control expert in the world

Suncenter  >  AI - Page Sitemap  >  stable hydrostatic pressure test system bulk production for pressurization
stable hydrostatic pressure test system bulk production for pressurization

Stable hydrostatic pressure test system bulk production for pressurization

MOQ
1 Set
Brand Name
SUNCENTER
Certificate
ISO/CE/SGS
Warranty
13 Months
Packaging
By Plywood case
Shipping Port
Shenzhen/Hongkong
Payment
T/T,Western Union,Credit card.
Transaction method
EXW,FOB,DDP,CIF,CFR
Place of Origin
Guangdong Province, China (Mainland)
Delivery Time
Within 10-15 working days after received deposit
Price
Get Latest Price
Get the latest price
Quantity Needed:
Pieces
E-mail:
Application Scope
Suncenter Fluid Control Equipment's gas booster is mostly used in the following scenes.While providing quality products, Suncenter Fluid Control Equipment is dedicated to providing personalized solutions for customers according to their needs and actual situations.
Product Comparison
Compared with same kind of products in the industry, gas booster has the following highlights due to the better technical capability.
Company Advantages
1. In the development stage, the material of Suncenter hydraulic pump test bench is subjected to many tests such as rubbing fastness test and a water repellency test.
2. The product features high dimensional accuracy. The dimension tolerance is controlled within limits starting from the very beginning stage of pattern making.
3. This product features the required dimensional stability. Various pre-treatments such as washing and dry cleaning have been applied to this product to test this property.
4. Dongguan Suncenter Fluid Control Equipment Co., Ltd constantly develops new hydrostatic pressure test products in view of market demands.
5. Dongguan Suncenter Fluid Control Equipment Co., Ltd is famous for its top quality of hydrostatic pressure test and professional after-sales services.

Gas booster pressure test bench


Suncenter - Air/Gas pressure test bench are compact and delicacy solution tailored to customer specific requirements with gas(air) boosters as well as all accessories to be fitted and installed in the frame or a closed cabinet.


To operate this system, the pressure gauges, valves and pressure regulators have to be fitted on panels. The outlet pressure is easily to be set through a simple air regulator.


The pump stops automatically when this end pressure is reached and restarts with a slight drop in the outlet pressure or an increase in the air drive pressure.


Operating pressure up to 80 MPa, for higher pressure, pump with double driven heads is an ideal option.


stable hydrostatic pressure test system bulk production for pressurization-1



The hottest selling- Model C frame type cabinet picture


stable hydrostatic pressure test system bulk production for pressurization-2
  • The standard gas booster pumps system including following parts:

  • Air –driven gas booster pump (DGA/DGD/DGT three series for choosing)

  • Stainless steel (carbon steel) material cabinet (Three models for choosing)

  • F.R.L combination for driven air (adjusts air pressure, add lubricating oil and water filter)

  • Driven air switch (Pump starting switch), driven air pressure gauge

  • Gas inlet switch, Gas inlet pressure gauge

  • Gas outlet switch, Gas outlet pressure gauge,  unloading valve, interconnecting pipes etc.

  • And we could also customize it according to clients’ special requirement.


stable hydrostatic pressure test system bulk production for pressurization-3
  • DGS series air/gas pressure test bench with round chart recorder


Model

Pressure boost ratio

Min. gas
Inlet pressure
PA (bar)

Max.gas
Inlet pressure
PA (bar)

Max. gas
outlet pressure PB (bar)

 Driven air pressure  PL

Formula to
calculate gas outlet pressure PB

Connection:
Gas Inlet /
Gas outlet (ZG thread)

Max. flow at driven air pressure of 6bar (L/min)

DGS-DGA02

2:1

1.0

16

16

2-8 bar

2X PL

1/2 / 1/2

960 (at PA of 6 bar )

DGS-DGA05

5:1

0

40

40

2-8 bar

5XPL

1/2 / 1/2

680(at PA of 6 bar )

DGS-DGA10

10:1

3.5

80

80

2-8 bar

10XPL

3/8/ 3/8

210(at PA of 10 bar )

DGS-DGA25

25:1

7.0

200

200

2-8 bar

25XPL

1/4/ 1/4

120(at PA of 20 bar )

DGS-DGA40

40:1

10

320

320

2-8 bar

40XPL

1/4/ 1/4

200(at PA of 40 bar )

DGS-DGA60

60:1

20

480

480

2-8 bar

60XPL

1/4/ 1/4

180(at PA of 40 bar )

DGS-DGA100

100:1

25

800

800

2-8 bar

100XPL

1/4/ M14X1.5

136(at PA of 40 bar )

DGS-DGA130

130:1

35

800

1040

2-8 bar

130XPL

1/4/ M14X1.5

120(at PA of 40 bar )


Technical specification for DGS-DGD series


Model

Pressure boost ratio

Min. gas
Inlet pressure
PA (bar)

Max.gas
Inlet pressure
PA (bar)

Max. gas 

outlet pressure PB (bar)

 Driven air pressure  PL

Formula to
calculate gas outlet pressure PB

Connection:
Gas Inlet /
Gas outlet (ZG thread)

Max. flow at driven air pressure of 6bar (L/min)

DGS-DGD10

10:1

3.5

80

80

2-8 bar

10XPL+ PA

3/8/3/8

410(at PA of 6 bar )

DGS-DGD25

25:1

10

200

200

2-8 bar

25XPL+ PA

1/4/1/4

396(at PA of 20 bar )

DGS-DGD40

40:1

15

320

320

2-8 bar

40XPL+ PA

1/4/1/4

320(at PA of 40 bar )

DGS-DGD60

60:1

25

480

480

2-8 bar

60XPL+ PA

1/4/1/4

215(at PA of 40 bar )

DGS-DGD100

100:1

35

800

800

2-8 bar

100XPL+ PA

1/4/M14*1.5

300(at PA of 60 bar )


Technical specification for DGS-DGT series


Model

Pressure boost ratio

Min. gas
Inlet pressure
PA (bar)

Max.gas
Inlet pressure
PA (bar)

Max. gas
outlet pressure PB (bar)

 Driven air pressure  PL

Formula to
calculate gas outlet pressure PB

Connection:
Gas Inlet /
Gas outlet (ZG thread)

Max. flow at driven air pressure of 6bar (L/min)

DGS-DGT25

25:1

0.1

10

200

 2-8 bar

25XPL+3.5XPA

1/4/ 1/4

136(at PA of 8 bar )

DGS-DGT40

40:1

0.1

10

320

2-8 bar

40XPL+ 6XPA

 1/4/1/4

124(at PA of 8 bar )

 DGS-DGT10/60

10:1/60:1

0.1

10

480

2-8 bar

60XPL+6X PA

 1/4/1/4

84(at PA of 8 bar )

DGS-DGT25/60

25:1/60:1

10

25

480

2-8 bar

60XPL+2.5XPA

 1/4/1/4

80(at PA of 15 bar )

DGS-DGT100

100:1

0.1

10

800

2-8 bar

100XPL+10XPA

1/4/ M14*1.5

63(at PA of 8 bar )


video





Company Features
1. Suncenter has been working on providing the most competitive hydrostatic pressure test and offering the one-stop services.
2. We have the most advanced production equipment and advanced technical equipment. They allow the company to produce every piece accurately and consistently.
3. Dongguan Suncenter Fluid Control Equipment Co., Ltd attaches importance to supervision and evaluation to fully enhance brand awareness, social reputation and loyalty. Welcome to visit our factory! The innovation mechanism will be adhered by 企业名称 to adapt to the market. Welcome to visit our factory!
In the production of Suncenter hydrostatic pressure test, fabrics with international certification and in conformity with regulations of particular importance to the environment and human health are used.
The necessary tests for Suncenter hydrostatic pressure test have been conducted. It has been tested with regard to formaldehyde content, lead content, structural stability, static loading, colors, and texture.
Suncenter hydraulic pump test bench materials have been tested to eliminate any chemicals that have a negative impact on health.
Suncenter hydraulic pump test bench will go through a comprehensive inspection, including its internal stress, fatigue resistance, dimensional accuracy, surface treatment effect, and other mechanical properties.
Suncenter hydrostatic pressure test has to go through a series of tests. These tests are conducted to verify compliance with the machinery directive, operation safety, and life expectancy.
The company strictly controls product quality and production costs, strives to reduce procurement costs in production, strengthens material management, reduces material consumption, establishes a complete quality management system in terms of product quality, and adopts strict quality inspection measures to ensure that [ 10368] are high-quality products with high cost performance.
Product Message
Chat Online 编辑模式下无法使用
Leave Your Message inputting...