Become the first-class high pressure fluid control expert in the world

sales@chinasuncenter.com

Suncenter co2 fire extinguisher refill for fire extinguisher-Suncenter-imgEnglish
Suncenter  > 

AI - Page Sitemap

 > 

Suncenter co2 fire extinguisher refill for fire extinguisher

Suncenter co2 fire extinguisher refill for fire extinguisher

Suncenter co2 fire extinguisher refill for fire extinguisher

MOQ
1 Set
Brand Name
SUNCENTER
Certificate
ISO/CE/SGS
Warranty
13 Months
Packaging
By Plywood case
Shipping Port
Shenzhen/Hongkong
Payment
T/T,Western Union,Credit card.
Transaction method
EXW,FOB,DDP,CIF,CFR
Place of Origin
Guangdong Province, China (Mainland)
Delivery Time
Within 10-15 working days after received deposit
Price
Get Latest Price
Get the latest price
Quantity Needed:
Pieces
E-mail:

DGS-FM-5A model automatic FM200 filling machine


Solution A (DGS-FM-5A) added the sensors, electromagnetic valve, vacuum pump, and the electronic scale based on solution B (manual control),it is automatic control mode


Suncenter co2 fire extinguisher refill for fire extinguisher-1
  • Main parameters:

  • The driving source: compressed air (by air compressor, need 3-8 bar air pressure)

  • Medium: FM200/ NOVEC/Nitrogen

  • Boost ratio: 5:1

  • Output pressure: 4.2 Mpa/5.3Mpa

  • Driven air inlet port: fast insert 12 per cent

  • Nitrogen/FM200 inlet port: ZG3/8 internal thread

  • High pressure gas outlet port: ZG3/8 internal thread

  • Electric scale range:0-500kg(there is also max 1000kg for optional)


DGS-DGGD16 model liquid CO2 filling equipment


Suncenter co2 fire extinguisher refill for fire extinguisher-2
  • The CO2 Fire Extinguisher filling equipment including following parts:

  • Air–driven liquid CO2 gas booster pump

  • Stainless steel material cabinet

  • F.R.L combination for driven air (adjusts air pressure, add lubricating oil and water filter)

  • Driven air switch (Pump starting switch), driven air pressure gauge

  • Gas inlet switch, Gas inlet pressure gauge

  • Gas outlet switch, Gas outlet pressure gauge, unloading valve, interconnecting pipes etc.

  • And we could also customize it according to clients’special requirement.


Model

Pressure Ratio

Driven air pressure PL 

Formula to calculate outlet pressure

MAX Outlet
     Pressure(bar)*

Driven
     air inlet port

High pressure Outlet port

MAX Flow
     (L/min)**

DGS-DGG16

16:1

3-8 bar

16XPL

128

G 1/2

NPT/ZG

12.42

DGS-DGG28

28:1

3-8 bar

28XPL

224

G 1/2

NPT/ZG

7.11

DGS-DGGD166

16:1

3-8 bar

16XPL

128

G 1/2

NPT/ZG

19.73

DGS-DGGD28

28:1

3-8 bar

28XPL

224

G 1/2

NPT/ZG

11.30


DGS-CO2-B model liquid CO2(fire extinguisher) filling machine


Suncenter co2 fire extinguisher refill for fire extinguisher-3
  • Main parameters:

  • The driving source: compressed air (by air compressor, need 3-8 bar air pressure)

  • Medium: CO2

  • Max output pressure: 12.8Mpa

  • Driven air inlet port: fast insert 12 per cent

  • Liquid CO2 inlet port: ZG3/8 internal thread

  • High pressure gas outlet port: ZG3/8 internal thread


Fire Extinguisher filling


Suncenter co2 fire extinguisher refill for fire extinguisher-4
Suncenter co2 fire extinguisher refill for fire extinguisher-5


video





Suncenter automatic liquid filling machine has been evaluated in many aspects, including assessments on contaminants and harmful substances, material resistance to bacteria and fungi, and VOC&formaldehyde emission.
In the design stage of Suncenter automatic liquid filling machine, many factors have been taken into account. These considerations include fire resistance ability, safety hazards, structural comfort & stability, and the content of contaminants and harmful substances.
The design of Suncenter fire extinguisher refill is completed. It is carried out by our designers who have a unique understanding of current furniture styles or forms.
The design of Suncenter fire extinguisher refill is professional. It is conceived by designers who have a good understanding of the Alignment of objects, Similarity of colour/pattern/texture, Continuation and Overlapping of space design elements, etc.
Suncenter automatic liquid filling machine is created in a professional way. Conducted by exceptional interior designers, the design, including elements of shapes, color mix, and style is done in line with the market trends.
A strict quality assurance system has been established to ensure the quality of the product.
The usability and service life of this product are ensured by our qualified QC team.
We have a complete set of quality assurance system and sophisticated testing equipment to ensure its quality.
A quality assurance system has been established and improved to place the product's performance indicators at the forefront of the industry.
The product is superior in quality and reliable in performance.
The quality of this product is well controlled by implementing strict testing process.
Dongguan Suncenter Fluid Control Equipment Co., Ltd has a creative and professional fire extinguisher refill design team and skilled staff.
With the principle of 'Customers First', Dongguan Suncenter Fluid Control Equipment Co., Ltd has set up several market service centers for our customers.
The result shows: our fire extinguisher refill has met the requirements of the fire extinguisher refill standard, the process has advantages of fire extinguisher refill.
Dongguan Suncenter Fluid Control Equipment Co., Ltd has more advantages in fire extinguisher refill than others in China.
The quality of every automatic liquid filling machine will be inspected before loading.
fire extinguisher refill is available for fire extinguisher refill and international certificate as fire extinguisher refill.
Product Message