Become the first-class high pressure fluid control expert in the world

Suncenter  >  AI - Page Sitemap  >  Suncenter pump hydrostatic pressure test for safety valve calibration
Suncenter pump hydrostatic pressure test for safety valve calibration

Suncenter pump hydrostatic pressure test for safety valve calibration

MOQ
1 Set
Brand Name
SUNCENTER
Certificate
ISO/CE/SGS
Warranty
13 Months
Packaging
By Plywood case
Shipping Port
Shenzhen/Hongkong
Payment
T/T,Western Union,Credit card.
Transaction method
EXW,FOB,DDP,CIF,CFR
Place of Origin
Guangdong Province, China (Mainland)
Delivery Time
Within 10-15 working days after received deposit
Price
Get Latest Price
Get the latest price
Quantity Needed:
Pieces
E-mail:

Gas booster pump system


Suncenter - Gas booster systems are compact and delicacy solution tailored to customer specific requirements with gas boosters as well as all accessories to be fitted and installed in the frame or a closed cabinet.


To operate this system, the pressure gauges, valves and pressure regulators have to be fitted on panels. The outlet pressure is easily to be set through a simple air regulator.


The pump stops automatically when this end pressure is reached and restarts with a slight drop in the outlet pressure or an increase in the air drive pressure.


Suncenter - Pneumatic booster system are used for oil free compression of clean shop air as well as industrial gases like Argon, Helium, Oxygen, Hydrogen and Nitrogen,CO2, etc..Driven air from 3 bar to 8 bar (from air compressor).


Operating pressure up to 80 MPa, for higher pressure, pump with double driven heads is an ideal option.


Suncenter DGS Series Pneumatic (Air driven) Gas Booster Pump System


Suncenter pump hydrostatic pressure test for safety valve calibration-1


DGS booster system = booster pump+ following valves, gages, and parts


Suncenter pump hydrostatic pressure test for safety valve calibration-2



The hottest selling- model A and model C cabinet picture


Suncenter pump hydrostatic pressure test for safety valve calibration-3
  • The standard gas booster pumps system including following parts:

  • Air –driven gas booster pump (DGA/DGD/DGT three series for choosing)

  • Stainless steel (carbon steel) material cabinet (Three models for choosing)

  • F.R.L combination for driven air (adjusts air pressure, add lubricating oil and water filter)

  • Driven air switch (Pump starting switch), driven air pressure gauge

  • Gas inlet switch, Gas inlet pressure gauge

  • Gas outlet switch, Gas outlet pressure gauge,  unloading valve, interconnecting pipes etc.

  • And we could also customize it according to clients’ special requirement.


Model

Pressure boost ratio

Min. gas
Inlet pressure
PA (bar)

Max.gas
Inlet pressure
PA (bar)

Max. gas
outlet pressure PB (bar)

 Driven air pressure  PL

Formula to
calculate gas outlet pressure PB

Connection:
Gas Inlet /
Gas outlet (NPT thread)

Max. flow at driven air pressure of 6bar (L/min)

DGS-DGA02

2:1

1.0

16

16

2bar-8 bar

2X PL

1/2 / 1/2

960 (at PA of 6 bar )

DGS-DGA05

5:1

0

40

40

2bar-8 bar

5XPL

1/2 / 1/2

680(at PA of 6 bar )

DGS-DGA06

6:1

2.0

48

48

2bar-8 bar

6XPL

1/2 / 1/2

360(at PA of 10 bar )

DGS-DGA10

10:1

3.5

80

80

2bar-8 bar

10XPL

3/8/ 3/8

210(at PA of 10 bar )

DGS-DGA15

15:1

3.5

120

120

2bar-8 bar

15XPL

3/8/ 3/8

190(at PA of 10 bar )

DGS-DGA25

25:1

7.0

200

200

2bar-8 bar

25XPL

1/4/ 1/4

120(at PA of 20 bar )

DGS-DGA40

40:1

10

320

320

2bar-8 bar

40XPL

1/4/ 1/4

200(at PA of 40 bar )

DGS-DGA60

60:1

20

480

480

2bar-8 bar

60XPL

1/4/ 1/4

180(at PA of 40 bar )

DGS-DGA100

100:1

25

800

800

2bar-8 bar

100XPL

1/4/ M14X1.5

136(at PA of 40 bar )


Technical specification for DGS-DGD Series:


Model

Pressure boost ratio

Min. gas
Inlet pressure
PA (bar)

Max.gas
Inlet pressure
PA (bar)

Max. gas
outlet pressure PB (bar)

 Driven air pressure  PL

Formula to
calculate gas outlet pressure PB

Connection:
Gas Inlet /
Gas outlet (NPT thread)

Max. flow at driven air pressure of 6bar (L/min)

DGS-DGD10

10:1

3.5

80

80

2bar-8 bar

10XPL+ PA

3/8/3/8

410(at PA of 6 bar )

DGS-DGD15

15:1

5

120

120

2bar-8 bar

15XPL+ PA

3/8/3/8

350 (at PA of 6 bar )

DGS-DGD25

25:1

10

200

200

2bar-8 bar

25XPL+ PA

1/4/1/4

396(at PA of 20 bar )

DGS-DGD40

40:1

15

320

320

2bar-8 bar

40XPL+ PA

1/4/1/4

320(at PA of 40 bar )

DGS-DGD60

60:1

25

480

480

2bar-8 bar

60XPL+ PA

1/4/1/4

215(at PA of 40 bar )

DGS-DGD100

100:1

35

800

800

2bar-8 bar

100XPL+ PA

1/4/M14*1.5

300(at PA of 60 bar )

DGS-DGD130

130:1

50 

1040

1040 

2bar-8 bar

130XPL+ PA

1/4/M14*1.5

180(at PA of 60 bar )


Technical specification for DGS-2DGD Series:


Model

Pressure boost ratio

Min. gas
   Inlet pressure
PA (bar)

Max.gas
Inlet pressure
PA (bar)

Max. gas
outlet pressure PB (bar)

 Driven air pressure  PL

Formula to
calculate gas outlet pressure PB

Connection:
Gas Inlet /
Gas outlet (NPT thread)

Max. flow at driven air pressure of 6bar (L/min)

DGS-2DGD10

10:1

3

80

80

2bar-8 bar

10XPL+ PA

1/2 / 1/2

980(at PA of 6 bar )

DGS-2DGD25

25:1

6

200

200

2bar-8 bar

25XPL+ PA

3/8 / 3/8

560(at PA of 10 bar )

DGS-2DGD40

40:1

25

320

320

2bar-8 bar

40XPL+ PA

3/8 / 3/8

480(at PA of 40 bar )

DGS-2DGD60

60:1

30

480

480

2bar-8 bar

60XPL+ PA

3/8 / 3/8

320(at PA of 40 bar )


Technical specification for DGS-DGT Series:


Model

Pressure boost ratio

Min. gas
Inlet pressure
PA (bar)

Max.gas
Inlet pressure
PA (bar)

Max. gas
outlet pressure PB (bar)

 Driven air pressure  PL

Formula to
calculate gas outlet pressure PB

Connection:
Gas Inlet /
Gas outlet (NPT thread)

Max. flow at driven air pressure of 6bar (L/min)

DGS-DGT15

15:1

0.1

56

120

2-8 bar

15XPL

3/8/ 1/4

230(at PA of 8 bar )

DGS-DGT25

25:1

0.1

10

200

2-8 bar

25XPL

3/8/ 1/4

156(at PA of 8 bar )

DGS-DGT7/25

25:1

5

56

200

2-8 bar

25XPL

3/8/ 1/4

156(at PA of 8 bar )

DGS-DGT40

40:1

0.1

10

320

2-8 bar

40XPL

3/8/ 1/4

124(at PA of 8 bar )

DGS-DGT15/40

40:1

5

120

320

2-8 bar

40XPL

3/8/ 1/4

124(at PA of 8 bar )

DGS-DGT60

60:1

0.1

10

480

2-8 bar

60XPL

3/8/ 1/4

80(at PA of 15 bar )

DGS-DGT15/60

60:1

6

120

480

2-8 bar

60XPL

3/8/ 1/4

80(at PA of 15 bar )

DGS-DGT100

100:1

0.1

10

800

2-8 bar

100XPL

3/8/ 1/4

63(at PA of 8 bar )


Technical specification for DGS-2DGT series:


Model

Pressure boost ratio

Min. gas
Inlet pressure
PA (bar)

Max.gas
Inlet pressure
PA (bar)

Max. gas
outlet pressure PB (bar)

 Driven air pressure  PL

Formula to
calculate gas outlet pressure PB

Connection:
Gas Inlet /
Gas outlet (NPT thread)

Max. flow at driven air pressure of 6bar (L/min)

DGS-2DGT7/15

15:1

4

56

120

2bar-8 bar

15XPL

3/8 / 3/8

430(at PA of 10 bar )

DGS-2DGT7/25

25:1

5

56

200

2bar-8 bar

25XPL

3/8 / 3/8

300(at PA of 10 bar )

DGS-2DGT15/40

40:1

7

120

320

2bar-8 bar

40XPL

3/8 / 3/8

180(at PA of 10 bar )

DGS-2DGT15/60

60:1

7

120

480

2bar-8 bar

60XPL

3/8 / 3/8

120(at PA of 10 bar )


Suncenter pump hydrostatic pressure test for safety valve calibration-4



Suncenter pump hydrostatic pressure test for safety valve calibration-5
  • DGS series gas boosters working pictures


Suncenter pump hydrostatic pressure test for safety valve calibration-6


DGS-DGD40 gas booster system for nitrogen gas spring filling

Suncenter pump hydrostatic pressure test for safety valve calibration-7


DGS-DGT series gas boosters for gas cylinder transfer and filling


video





Suncenter hydrostatic pressure test has been tested for guaranteed electrical safety. It has passed international tests for electric appliances such as insulation, electric leakage, plug performance, and grounding lead tests. This product has a high level of insulation
Suncenter hydrostatic pressure test has been tested. It is tested and certified by the Electrical and Mechanical Services Department, meeting the requirements of the Mandatory Energy Efficiency Labelling Scheme (MEELS) and Voluntary Energy Efficiency Labelling Scheme (VEELS). This product features very low no-load losses
The coil springs Suncenter hydrostatic pressure test contains could be between 250 and 1,000. And a heavier gauge of wire will be used if customers require fewer coils. This product has the feature of explosion-proof
Suncenter pressure test bench is designed based on extensive research, testing and knowledge to create the optimal balance of waterproofing, tear strength and weight. This product has the ability to accurately convert a physical parameter into a signal
Suncenter pressure test bench meets the highest appliance standards. It has passed tests in terms of voltage compatibility, electromagnetic safety, frequency stability, and plug safety. This product has been certified under CE and RoHS
The product has properties of long service, excellent and stable performance. This product can repeat the same measurement many times
Product Message
Chat Online 编辑模式下无法使用
Leave Your Message inputting...