Become the first-class high pressure fluid control expert in the world

Suncenter  >  AI - Page Sitemap  >  Suncenter safe gas booster system bulk production for safety valve calibration
Suncenter safe gas booster system bulk production for safety valve calibration

Suncenter safe gas booster system bulk production for safety valve calibration

MOQ
1 Set
Brand Name
SUNCENTER
Certificate
ISO/CE/SGS
Warranty
13 Months
Packaging
By Plywood case
Shipping Port
Shenzhen/Hongkong
Payment
T/T,Western Union,Credit card.
Transaction method
EXW,FOB,DDP,CIF,CFR
Place of Origin
Guangdong Province, China (Mainland)
Delivery Time
Within 10-15 working days after received deposit
Price
Get Latest Price
Get the latest price
Quantity Needed:
Pieces
E-mail:
Product Details
With a focus on details, Suncenter Fluid Control Equipment strives to create high-quality booster pumps.
  • Suncenter-gas booster | Gas booster pump | Suncenter
Company Advantages
1. Before delivery, Suncenter gas booster system has to undergo a wide range of tests. It is strictly tested in terms of the strength of its materials, statics&dynamics performance, resistance to vibrations&fatigue, etc.
2. The product is durable, fully functional and has a long service life.
3. This product is durable, cost-effective, well received by customers.
4. By using this product, business owners will less likely to witness workplace accidents and workman’s compensation claims.
5. The product is easy for people to control and only needs a little workforce. This will help lower operating costs.

Compressed Air Driven Gas Booster Pump- DGA/DGD/DGT Series


Suncenter Air Driven Gas Boosters provide for pressures up to 80Mpa (11,600 psi). Used for virtually all known gases, these boosters are ideal for increasing gas pressure, transferring high pressure gas, charging cylinders and scavenging. Key features include:


Applications for Air Driven Gas Boosters


SUNCENTER Air Driven Gas Boosters provide for pressures up to 80Mpa. Used for oil free compression not only of air or Nitrogen, but also flammable and risk gases like hydrogen, oxygen and natural gas. These boosters are ideal for increasing gas pressure, transferring high pressure gas, charging cylinders and scavenging.


Air driven boosters are an efficient alternative instead of electrically driven products and can be used in explosion- proof areas.


As a result of the wide range of models it is possible to select the optimum booster for each application. Single stage, double acting or two stage boosters or a combination of these models can be used to achieve different operating pressures and flow capacities.


SUNCENTER Air Driven Gas Boosters are ideal and widely used for hydrostatic and burst testing for valves, pipes, tubing and pressure vessels; Calibration for safety valves; Automobile regulator detecting and telecommunication cable inflatable appliances.


Suncenter safe gas booster system bulk production for safety valve calibration-1



DGA series gas booster pumps(Single acting, single air drive head):


Suncenter safe gas booster system bulk production for safety valve calibration-2
  • DGA pumps are available with high quality seals, which provide significantly better service life as well. Pump head fitted with exhaust cooling devices. All parts in contact with the gas are made of stainless steel.


Model

Pressure boost ratio

Min. gas Inlet pressure PA (bar)

Max.gas Inlet pressure PA (bar)

Max. gas
outlet pressure PB (bar)

 Driven air pressure PL

Formula to
calculate gas outlet pressure PB

Connection:
Gas Inlet /
Gas outlet (NPT thread)

Max. flow at driven air pressure of 6bar (L/min)

DGA02

2:1

1.0

16

16

2bar-8 bar

2X PL

1/2 / 1/2

960 (at PA of 6 bar )

DGA05

5:1

0

40

40

2bar-8 bar

5XPL

1/2 / 1/2

680(at PA of 6 bar )

DGA06

6:1

2.0

48

48

2bar-8 bar

6XPL

1/2 / 1/2

360(at PA of 10 bar )

DGA10

10:1

3.5

80

80

2bar-8 bar

10XPL

3/8/ 3/8

210(at PA of 10 bar )

GA15

15:1

3.5

120

120

2bar-8 bar

15XPL

3/8/ 3/8

190(at PA of 10 bar )

DGA25

25:1

7.0

200

200

2bar-8 bar

25XPL

1/4/ 1/4

120(at PA of 20 bar )

DGA40

40:1

10

320

320

2bar-8 bar

40XPL

1/4/ 1/4

200(at PA of 40 bar )

DGA60

60:1

20

480

480

2bar-8 bar

60XPL

1/4/ 1/4

180(at PA of 40 bar )

DGA100

100:1

25

800

800

2bar-8 bar

100XPL

1/4/ M14X1.5

136(at PA of 40 bar )


DGD series gas booster pumps(Double acting ):


Suncenter safe gas booster system bulk production for safety valve calibration-3
  • DGD series pumps are double acting, with single air driven heads type.   

  • DGD pumps are available with high quality seals, which provide significantly better service life

  • Double pump heads with exhaust cooling devices. 

  • All components in contact with the gas are made of stainless steel. 

  • Pipes mounting way are available as customized.


Model

Pressure boost ratio

Min. gas
Inlet pressure
     PA (bar)

Max.gas
Inlet pressure
     PA (bar)

Max. gas
outlet pressure PB (bar)

 Driven air pressure  PL

Formula to
calculate gas outlet pressure PB

Connection:
Gas Inlet /
Gas outlet (NPT thread)

Max. flow at driven air pressure of 6bar (L/min)

DGD10

10:1

3.5

80

80

2bar-8 bar

10XPL+ PA

3/8/3/8

410(at PA of 6 bar )

DGD15

15:1

5

120

120

2bar-8 bar

15XPL+ PA

3/8/3/8

350 (at PA of 6 bar )

DGD25

25:1

10

200

200

2bar-8 bar

25XPL+ PA

1/4/1/4

396(at PA of 20 bar )

DGD40

40:1

15

320

320

2bar-8 bar

40XPL+ PA

1/4/1/4

320(at PA of 40 bar )

DGD60

60:1

25

480

480

2bar-8 bar

60XPL+ PA

1/4/1/4

215(at PA of 40 bar )

DGD100

100:1

35

800

800

2bar-8 bar

100XPL+ PA

1/4/M14*1.5

300(at PA of 60 bar )

DGD130

130:1

50 

1040

1040 

2bar-8 bar

130XPL+ PA

1/4/M14*1.5

180(at PA of 60 bar )


2DGD series gas booster pumps(Double acting, double air driven heads ):


Suncenter safe gas booster system bulk production for safety valve calibration-4
  • Gas booster pump with max 800 bar outlet pressure


Model

Pressure boost ratio

Min. gas
Inlet pressure
PA (bar)

Max.gas
Inlet pressure
PA (bar)

Max. gas
outlet pressure PB (bar)

 Driven air pressure  PL

Formula to
calculate gas outlet pressure PB

Connection:
Gas Inlet /
Gas outlet (NPT thread)

Max. flow at driven air pressure of 6bar (L/min)

2DGD10

10:1

3

80

80

2bar-8 bar

10XPL+ PA

1/2 / 1/2

980(at PA of 6 bar )

2DGD25

25:1

6

200

200

2bar-8 bar

25XPL+ PA

3/8 / 3/8

560(at PA of 10 bar )

2DGD40

40:1

25

320

320

2bar-8 bar

40XPL+ PA

3/8 / 3/8

480(at PA of 40 bar )

2DGD60

60:1

30

480

480

2bar-8 bar

60XPL+ PA

3/8 / 3/8

320(at PA of 40 bar )


DGT series gas booster pumps(Double acting, double stage, single air drive head ):


Suncenter safe gas booster system bulk production for safety valve calibration-5
  • DGT pumps are double acting, double stage with single air drive head pumps. They can provide for super high pressure with very low inlet pressure. 

  • DGT pumps are available with high quality seals, which provide significantly better service life 

  • All parts in contact with the gas are made of stainless steel.


Model

Pressure boost ratio

Min. gas
Inlet pressure
PA (bar)

Max.gas
Inlet pressure
PA (bar)

Max. gas
outlet pressure PB (bar)

 Driven air pressure  PL

Formula to
calculate gas outlet pressure PB

Connection:
Gas Inlet /
Gas outlet (NPT thread)

Max. flow at driven air pressure of 6bar (L/min)

DGT15

15:1

0.1

56

120

2-8 bar

15XPL

3/8/ 1/4

230(at PA of 8 bar )

DGT25

25:1

0.1

10

200

2-8 bar

25XPL

3/8/ 1/4

156(at PA of 8 bar )

DGT7/25

25:1

5

56

200

2-8 bar

25XPL

3/8/ 1/4

156(at PA of 8 bar )

DGT40

40:1

0.1

10

320

2-8 bar

40XPL

3/8/ 1/4

124(at PA of 8 bar )

DGT15/40

40:1

5

120

320

2-8 bar

40XPL

3/8/ 1/4

124(at PA of 8 bar )

DGT60

60:1

0.1

10

480

2-8 bar

60XPL

3/8/ 1/4

80(at PA of 15 bar )

DGT15/60

60:1

6

120

480

2-8 bar

60XPL

3/8/ 1/4

80(at PA of 15 bar )

DGT100

100:1

0.1

10

800

2-8 bar

100XPL

3/8/ 1/4

63(at PA of 8 bar )


2DGT series gas booster pumps(Double acting, double stage,double air driven heads ):


Suncenter safe gas booster system bulk production for safety valve calibration-6
  • Gas booster pump with max 800 bar outlet pressure 


Model

Pressure boost ratio

Min. gas
Inlet pressure
PA (bar)

Max.gas
Inlet pressure
PA (bar)

Max. gas
outlet pressure PB (bar)

 Driven air pressure  PL

Formula to
calculate gas outlet pressure PB

Connection:
Gas Inlet /
Gas outlet (NPT thread)

Max. flow at driven air pressure of 6bar (L/min)

2DGT7/15

15:1

4

56

120

2bar-8 bar

15XPL

3/8 / 3/8

430(at PA of 10 bar )

2DGT7/25

25:1

5

56

200

2bar-8 bar

25XPL

3/8 / 3/8

300(at PA of 10 bar )

2DGT15/40

40:1

7

120

320

2bar-8 bar

40XPL

3/8 / 3/8

180(at PA of 10 bar )

2DGT15/60

60:1

7

120

480

2bar-8 bar

60XPL

3/8 / 3/8

120(at PA of 10 bar )



Suncenter DGS Series Pneumatic (Air driven) Gas Booster Pump System


Suncenter - Pneumatic gas booster system are compact and delicacy solution tailored to customer specific requirements with gas boosters as well as all accessories to be fitted and installed in the frame or a closed cabinet.


To operate this system, the pressure gauges, valves and pressure regulators have to be fitted on panels. The outlet pressure is easily to be set through a simple air regulator.


The pump stops automatically when this end pressure is reached and restarts with a slight drop in the outlet pressure or an increase in the air drive pressure.


Suncenter - Pneumatic booster system are used for oil free compression of clean shop air as well as industrial gases like Argon, Helium, Oxygen, Hydrogen and Nitrogen,CO2, etc..Driven air from 3 bar to 8 bar (from air compressor).


Operating pressure up to 80 MPa, for higher pressure, pump with double driven heads is an ideal option.


Suncenter safe gas booster system bulk production for safety valve calibration-7


Suncenter safe gas booster system bulk production for safety valve calibration-8


The hottest selling- model A and model C cabinet picture


Suncenter safe gas booster system bulk production for safety valve calibration-9
  • The standard gas booster pumps system including following parts:

  • Air –driven gas booster pump (DGA/DGD/DGT three series for choosing)

  • Stainless steel (carbon steel) material cabinet (Three models for choosing)

  • F.R.L combination for driven air (adjusts air pressure, add lubricating oil and water filter)

  • Driven air switch (Pump starting switch), driven air pressure gauge

  • Gas inlet switch, Gas inlet pressure gauge

  • Gas outlet switch, Gas outlet pressure gauge,  unloading valve, interconnecting pipes etc.

  • And we could also customize it according to clients’ special requirement.


Suncenter safe gas booster system bulk production for safety valve calibration-10
  • DGT series gas booster working picture 


Suncenter safe gas booster system bulk production for safety valve calibration-11


         Gas pressure booster for cylinder transfer and filling
Suncenter safe gas booster system bulk production for safety valve calibration-12


         DGS series gas booster system working picture



features

  •   Compressed Air driven - no electricity required (connect to normal air compressor)

  •   In order to extend the lifetime of the pump, the driving air pressure should not be higher than 8 bar

  •   No airline lubricator required

  •   Hydrocarbon free - separation between air and gas sections

  •   Pressures to 80Mpa (11,600 psi)

  •   Wide range of models with different ratios

  •   Built-in-cooling on most models

  •   Easy to install, operate and maintain

  •   Best price / performance ratio  

  •   No heat, flame or spark risk and explosion proof 

  •   Automatic pressure holding, whatever the cause of the pressure drop, the Suncenter   pump will automatically start, keep the loop pressure constant

  •   Applicable gas:Air/Ar(Argon)/He(Helium)/H2(Hydrogen)/O2(Oxygen)N2(Nitrogen) CO2/NO2/CH4/C2H2/LNG/LPG/CNG/FM200/SF6/H2S etc


video





Company Features
1. At present, the main business of Dongguan Suncenter Fluid Control Equipment Co., Ltd includes the R&D, production and sales of gas booster .
2. Dongguan Suncenter Fluid Control Equipment Co., Ltd has won numerous top prizes in China for its scientific and technological achievements.
3. We are active in business sustainable development. We will uphold business ethics throughout our production, such as reducing water consumption by recycling reusable water. We have aware of the importance of sustainability issues. We will make corresponding plans to set our actions to gear to achieve sustainable development, such as reducing waste and conserving energy resources. As a product manufacturer, we always look for materials that could be given a second life, continuously upgrade our packaging methods, and reducing resources wastes to improve sustainability. Integrity will become the heart and soul of our company's culture. In business activities, we will never cheat our partners, suppliers, and clients no matter what. We will always work hard to realize our commitment to them.
Suncenter gas booster system is designed with utmost accuracy. It is hypoallergenic and friendly to sensitive skin
Suncenter gas booster system is delicately manufactured and reflects a high level of technology. It is granted with certificates such as RoHS and SGS
The current international advanced surface treatment technology is used for Suncenter gas booster production. It lives up to the standards of the IKEA textile testing
Suncenter gas booster features a special design which is well-designed by our professional designers. It does not breed bacteria, which reduces the risk of cross-contamination
The production of Suncenter gas booster system adopts reasonable improvements. It has the ability to prevent oils from penetrating into it or from sticking to its surface
The product generates little noise. It is developed and manufactured based on the noise standards for the industrial equipment. It has the ability to prevent oils from penetrating into it or from sticking to its surface
Product Message
Chat Online 编辑模式下无法使用
Leave Your Message inputting...