loading

Become the first-class high pressure fluid control expert in the world

Suncenter  >  AI - Page Sitemap  >  Suncenter waterproof fire extinguisher refill factory price for fire extinguisher
Suncenter waterproof fire extinguisher refill factory price for fire extinguisher

Suncenter waterproof fire extinguisher refill factory price for fire extinguisher

MOQ
1 Set
Brand Name
SUNCENTER
Certificate
ISO/CE/SGS
Warranty
13 Months
Packaging
By Plywood case
Shipping Port
Shenzhen/Hongkong
Payment
T/T,Western Union,Credit card.
Transaction method
EXW,FOB,DDP,CIF,CFR
Place of Origin
Guangdong Province, China (Mainland)
Delivery Time
Within 10-15 working days after received deposit
Price
Get Latest Price
Get the latest price
Quantity Needed:
Pieces
E-mail:

DGS-FM-5A model automatic FM200 filling machine


Solution A (DGS-FM-5A) added the sensors, electromagnetic valve, vacuum pump, and the electronic scale based on solution B (manual control),it is automatic control mode


Suncenter waterproof fire extinguisher refill factory price for fire extinguisher-1
  • Main parameters:

  • The driving source: compressed air (by air compressor, need 3-8 bar air pressure)

  • Medium: FM200/ NOVEC/Nitrogen

  • Boost ratio: 5:1

  • Output pressure: 4.2 Mpa/5.3Mpa

  • Driven air inlet port: fast insert 12 per cent

  • Nitrogen/FM200 inlet port: ZG3/8 internal thread

  • High pressure gas outlet port: ZG3/8 internal thread

  • Electric scale range:0-500kg(there is also max 1000kg for optional)


DGS-DGGD16 model liquid CO2 filling equipment


Suncenter waterproof fire extinguisher refill factory price for fire extinguisher-2
  • The CO2 Fire Extinguisher filling equipment including following parts:

  • Air–driven liquid CO2 gas booster pump

  • Stainless steel material cabinet

  • F.R.L combination for driven air (adjusts air pressure, add lubricating oil and water filter)

  • Driven air switch (Pump starting switch), driven air pressure gauge

  • Gas inlet switch, Gas inlet pressure gauge

  • Gas outlet switch, Gas outlet pressure gauge, unloading valve, interconnecting pipes etc.

  • And we could also customize it according to clients’special requirement.


Model

Pressure Ratio

Driven air pressure PL 

Formula to calculate outlet pressure

MAX Outlet
     Pressure(bar)*

Driven
     air inlet port

High pressure Outlet port

MAX Flow
     (L/min)**

DGS-DGG16

16:1

3-8 bar

16XPL

128

G 1/2

NPT/ZG

12.42

DGS-DGG28

28:1

3-8 bar

28XPL

224

G 1/2

NPT/ZG

7.11

DGS-DGGD166

16:1

3-8 bar

16XPL

128

G 1/2

NPT/ZG

19.73

DGS-DGGD28

28:1

3-8 bar

28XPL

224

G 1/2

NPT/ZG

11.30


DGS-CO2-B model liquid CO2(fire extinguisher) filling machine


Suncenter waterproof fire extinguisher refill factory price for fire extinguisher-3
  • Main parameters:

  • The driving source: compressed air (by air compressor, need 3-8 bar air pressure)

  • Medium: CO2

  • Max output pressure: 12.8Mpa

  • Driven air inlet port: fast insert 12 per cent

  • Liquid CO2 inlet port: ZG3/8 internal thread

  • High pressure gas outlet port: ZG3/8 internal thread


Fire Extinguisher filling


Suncenter waterproof fire extinguisher refill factory price for fire extinguisher-4
Suncenter waterproof fire extinguisher refill factory price for fire extinguisher-5


video





The preparation process of Suncenter fire extinguisher filling equipment includes a few steps. Materials crushing, grinding, separating, and refining are conducted by professional technicians who have many years of experience in mineral extraction and refinery. It has the LED indicator to show the charging state
Suncenter fire extinguisher refill meets the regulatory requirements of the textile market. It has been scrutinized on the fiber strength, fiber stiffness, weaving fineness, seam force, moisture permeability. Featuring automatic thermal cut-off function, the product will not accumulate too much heat
Suncenter fire extinguisher refill goes through rigorous quality tests. Its light absorption, energy transforming, and energy utilization capacity are professionally tested in the field sites. The strong housing helps protect against scratches, bumps, and drops
Suncenter fire extinguisher filling equipment is processed with high-tech dyeing techniques. It will be dyed based on customers' requirements of different dyeing methods, mainly direct dyeing, mordant dyeing, overdye, or wet-on-wet dyeing. The product can withstand a wide range of operating temperature from -29ºC to +45.5ºC
Suncenter fire extinguisher filling equipment is rigorously tested. It has passed many tests: antibacterial & antimicrobial testing, slip resistance testing, shedding propensity testing, and stitching reinforcement strength testing. The built-in cooling fan protects this product form overheat
Our professional team implements quality control system to meet the most strict quality standards. Featuring automatic thermal cut-off function, the product will not accumulate too much heat
Product Message
Chat Online 编辑模式下无法使用
Leave Your Message inputting...