loading

Become the first-class high pressure fluid control expert in the world

Suncenter  >  AI - Page Sitemap  >  Suncenter system nitrogen pumps at discount for natural gas boosts pressure
Suncenter system nitrogen pumps at discount for natural gas boosts pressure

Suncenter system nitrogen pumps at discount for natural gas boosts pressure

MOQ
1 Set
Brand Name
SUNCENTER
Certificate
ISO/CE/SGS
Warranty
13 Months
Packaging
By Plywood case
Shipping Port
Shenzhen/Hongkong
Payment
T/T,Western Union,Credit card.
Transaction method
EXW,FOB,DDP,CIF,CFR
Place of Origin
Guangdong Province, China (Mainland)
Delivery Time
Within 10-15 working days after received deposit
Price
Get Latest Price
Get the latest price
Quantity Needed:
Pieces
E-mail:
Product Details
With the pursuit of excellence, Suncenter Fluid Control Equipment is committed to showing you unique craftsmanship in details.
  • product-Suncenter-img-1
Application Scope
The hydro test pump produced by Suncenter Fluid Control Equipment is very popular in the market and is widely used in industry.Suncenter Fluid Control Equipment provides comprehensive and reasonable solutions based on customer's specific situations and needs.
  • product-Suncenter-img-1
Company Advantages
1. Suncenter has established stable business relationship and service networks in many countries.
2. The product features an easy-to-clean surface. It is either easy to adhere to dust or dirt not retain water stain.
3. People are happy that this product helps them get rid of smelly feet because no proliferation of bacteria and fungi and the bad odor produced.
4. The product looks great and clean. It is especially great for families and groups of friends to create fun and memories. - One of the visitors says.

Gas booster pump system


Suncenter - Gas booster systems are compact and delicacy solution tailored to customer specific requirements with gas boosters as well as all accessories to be fitted and installed in the frame or a closed cabinet.


To operate this system, the pressure gauges, valves and pressure regulators have to be fitted on panels. The outlet pressure is easily to be set through a simple air regulator.


The pump stops automatically when this end pressure is reached and restarts with a slight drop in the outlet pressure or an increase in the air drive pressure.


Suncenter - Pneumatic booster system are used for oil free compression of clean shop air as well as industrial gases like Argon, Helium, Oxygen, Hydrogen and Nitrogen,CO2, etc..Driven air from 3 bar to 8 bar (from air compressor).


Operating pressure up to 80 MPa, for higher pressure, pump with double driven heads is an ideal option.


Suncenter DGS Series Pneumatic (Air driven) Gas Booster Pump System


Suncenter system nitrogen pumps at discount for natural gas boosts pressure-1


DGS booster system = booster pump+ following valves, gages, and parts


Suncenter system nitrogen pumps at discount for natural gas boosts pressure-2



The hottest selling- model A and model C cabinet picture


Suncenter system nitrogen pumps at discount for natural gas boosts pressure-3
  • The standard gas booster pumps system including following parts:

  • Air –driven gas booster pump (DGA/DGD/DGT three series for choosing)

  • Stainless steel (carbon steel) material cabinet (Three models for choosing)

  • F.R.L combination for driven air (adjusts air pressure, add lubricating oil and water filter)

  • Driven air switch (Pump starting switch), driven air pressure gauge

  • Gas inlet switch, Gas inlet pressure gauge

  • Gas outlet switch, Gas outlet pressure gauge,  unloading valve, interconnecting pipes etc.

  • And we could also customize it according to clients’ special requirement.


Model

Pressure boost ratio

Min. gas
Inlet pressure
PA (bar)

Max.gas
Inlet pressure
PA (bar)

Max. gas
outlet pressure PB (bar)

 Driven air pressure  PL

Formula to
calculate gas outlet pressure PB

Connection:
Gas Inlet /
Gas outlet (NPT thread)

Max. flow at driven air pressure of 6bar (L/min)

DGS-DGA02

2:1

1.0

16

16

2bar-8 bar

2X PL

1/2 / 1/2

960 (at PA of 6 bar )

DGS-DGA05

5:1

0

40

40

2bar-8 bar

5XPL

1/2 / 1/2

680(at PA of 6 bar )

DGS-DGA06

6:1

2.0

48

48

2bar-8 bar

6XPL

1/2 / 1/2

360(at PA of 10 bar )

DGS-DGA10

10:1

3.5

80

80

2bar-8 bar

10XPL

3/8/ 3/8

210(at PA of 10 bar )

DGS-DGA15

15:1

3.5

120

120

2bar-8 bar

15XPL

3/8/ 3/8

190(at PA of 10 bar )

DGS-DGA25

25:1

7.0

200

200

2bar-8 bar

25XPL

1/4/ 1/4

120(at PA of 20 bar )

DGS-DGA40

40:1

10

320

320

2bar-8 bar

40XPL

1/4/ 1/4

200(at PA of 40 bar )

DGS-DGA60

60:1

20

480

480

2bar-8 bar

60XPL

1/4/ 1/4

180(at PA of 40 bar )

DGS-DGA100

100:1

25

800

800

2bar-8 bar

100XPL

1/4/ M14X1.5

136(at PA of 40 bar )


Technical specification for DGS-DGD Series:


Model

Pressure boost ratio

Min. gas
Inlet pressure
PA (bar)

Max.gas
Inlet pressure
PA (bar)

Max. gas
outlet pressure PB (bar)

 Driven air pressure  PL

Formula to
calculate gas outlet pressure PB

Connection:
Gas Inlet /
Gas outlet (NPT thread)

Max. flow at driven air pressure of 6bar (L/min)

DGS-DGD10

10:1

3.5

80

80

2bar-8 bar

10XPL+ PA

3/8/3/8

410(at PA of 6 bar )

DGS-DGD15

15:1

5

120

120

2bar-8 bar

15XPL+ PA

3/8/3/8

350 (at PA of 6 bar )

DGS-DGD25

25:1

10

200

200

2bar-8 bar

25XPL+ PA

1/4/1/4

396(at PA of 20 bar )

DGS-DGD40

40:1

15

320

320

2bar-8 bar

40XPL+ PA

1/4/1/4

320(at PA of 40 bar )

DGS-DGD60

60:1

25

480

480

2bar-8 bar

60XPL+ PA

1/4/1/4

215(at PA of 40 bar )

DGS-DGD100

100:1

35

800

800

2bar-8 bar

100XPL+ PA

1/4/M14*1.5

300(at PA of 60 bar )

DGS-DGD130

130:1

50 

1040

1040 

2bar-8 bar

130XPL+ PA

1/4/M14*1.5

180(at PA of 60 bar )


Technical specification for DGS-2DGD Series:


Model

Pressure boost ratio

Min. gas
   Inlet pressure
PA (bar)

Max.gas
Inlet pressure
PA (bar)

Max. gas
outlet pressure PB (bar)

 Driven air pressure  PL

Formula to
calculate gas outlet pressure PB

Connection:
Gas Inlet /
Gas outlet (NPT thread)

Max. flow at driven air pressure of 6bar (L/min)

DGS-2DGD10

10:1

3

80

80

2bar-8 bar

10XPL+ PA

1/2 / 1/2

980(at PA of 6 bar )

DGS-2DGD25

25:1

6

200

200

2bar-8 bar

25XPL+ PA

3/8 / 3/8

560(at PA of 10 bar )

DGS-2DGD40

40:1

25

320

320

2bar-8 bar

40XPL+ PA

3/8 / 3/8

480(at PA of 40 bar )

DGS-2DGD60

60:1

30

480

480

2bar-8 bar

60XPL+ PA

3/8 / 3/8

320(at PA of 40 bar )


Technical specification for DGS-DGT Series:


Model

Pressure boost ratio

Min. gas
Inlet pressure
PA (bar)

Max.gas
Inlet pressure
PA (bar)

Max. gas
outlet pressure PB (bar)

 Driven air pressure  PL

Formula to
calculate gas outlet pressure PB

Connection:
Gas Inlet /
Gas outlet (NPT thread)

Max. flow at driven air pressure of 6bar (L/min)

DGS-DGT15

15:1

0.1

56

120

2-8 bar

15XPL

3/8/ 1/4

230(at PA of 8 bar )

DGS-DGT25

25:1

0.1

10

200

2-8 bar

25XPL

3/8/ 1/4

156(at PA of 8 bar )

DGS-DGT7/25

25:1

5

56

200

2-8 bar

25XPL

3/8/ 1/4

156(at PA of 8 bar )

DGS-DGT40

40:1

0.1

10

320

2-8 bar

40XPL

3/8/ 1/4

124(at PA of 8 bar )

DGS-DGT15/40

40:1

5

120

320

2-8 bar

40XPL

3/8/ 1/4

124(at PA of 8 bar )

DGS-DGT60

60:1

0.1

10

480

2-8 bar

60XPL

3/8/ 1/4

80(at PA of 15 bar )

DGS-DGT15/60

60:1

6

120

480

2-8 bar

60XPL

3/8/ 1/4

80(at PA of 15 bar )

DGS-DGT100

100:1

0.1

10

800

2-8 bar

100XPL

3/8/ 1/4

63(at PA of 8 bar )


Technical specification for DGS-2DGT series:


Model

Pressure boost ratio

Min. gas
Inlet pressure
PA (bar)

Max.gas
Inlet pressure
PA (bar)

Max. gas
outlet pressure PB (bar)

 Driven air pressure  PL

Formula to
calculate gas outlet pressure PB

Connection:
Gas Inlet /
Gas outlet (NPT thread)

Max. flow at driven air pressure of 6bar (L/min)

DGS-2DGT7/15

15:1

4

56

120

2bar-8 bar

15XPL

3/8 / 3/8

430(at PA of 10 bar )

DGS-2DGT7/25

25:1

5

56

200

2bar-8 bar

25XPL

3/8 / 3/8

300(at PA of 10 bar )

DGS-2DGT15/40

40:1

7

120

320

2bar-8 bar

40XPL

3/8 / 3/8

180(at PA of 10 bar )

DGS-2DGT15/60

60:1

7

120

480

2bar-8 bar

60XPL

3/8 / 3/8

120(at PA of 10 bar )


Suncenter system nitrogen pumps at discount for natural gas boosts pressure-4



Suncenter system nitrogen pumps at discount for natural gas boosts pressure-5
  • DGS series gas boosters working pictures


Suncenter system nitrogen pumps at discount for natural gas boosts pressure-6


DGS-DGD40 gas booster system for nitrogen gas spring filling

Suncenter system nitrogen pumps at discount for natural gas boosts pressure-7


DGS-DGT series gas boosters for gas cylinder transfer and filling


video





Company Features
1. Engaging in the industry of nitrogen pumps, Dongguan Suncenter Fluid Control Equipment Co., Ltd is a remarkable enterprise.
2. To be one of the most influential enterprise, Suncenter has been doing its utmost to produce hydrostatic pressure test with high quality.
3. Our company is committed to sustainable manufacturing processes. All our manufacturing processes are designed with sustainability and efficiency in mind. Through treating employees fairly and ethically, we fulfill our social responsibility, which is especially true for disabled people or ethnic people. Please contact us! We have a highly motivated goal: to be a major global market player in this industry. Under this, we will invest in pooling talents to strengthen our R&D ability. We strive to achieve the goal through product innovation superiority.
The series of nitrogen pumps are air pressure testing, will bring the best result of air pressure testing for you. This product has been certified under CE and RoHS
hydrostatic pressure test adopt air pressure testing materials, generate features such as air pressure testing. This product features a frequency response property
hydrostatic pressure test are likely to possess features likeair pressure testing. This product has a wide range of operating temperatures
air pressure testing is designed as air pressure testing and provides air pressure testing solution. This product is easy to install and use
The production of air pressure testing always takes air pressure testing into account. This product is characterized by excellent temperature stability
The product has easy maintainance access. It is designed for accessibility for maintenance, complying with OSHA standards CFR 1910.66, CFR 1910.28 and ANSI/IWCA I-14.1 'Window Cleaning Safety Standard.' It is suitable for extreme pressure conditions
Product Message
Chat Online 编辑模式下无法使用
Leave Your Message inputting...