The safety of the plunger pump operation procedures

by:Suncenter     2020-08-27
Check reducer the fuel tank, three plunger high-pressure natural gas booster pump oil level and emulsion tank water level is on the oil level and water level. Check the safety valve, pressure gauge, water level indicator, liquid level indicator is sensitive and correct; Pressure gauge, safety valve calibration once a year, the relief valve on a regular basis for exhaust test, adhesion in case the valve core and valve hole plug. Check each part of the water pump, all valves, solenoid valves, pipes, etc are in good condition, can not have water, air, oil leakage, check the electrical zero ( Ground) Line is solid, stop the pump for more than a week, to measure the main motor insulation are in good condition; Check with hydraulic press signal is correct. Open/close the valve, - To stand in the stem profile, slow rotation. May not leave work at work, closely monitored control instrument and water level indicator light is normal, such as false water level, shall promptly adopt measures, and every 10 ~ 15 minutes for all equipment inspection tour again, record every hour operation, emulsion temperature shall not exceed 60 ℃, cooling water temperature shall not exceed 40 ℃, the motor temperature shall not exceed the rated temperature. Unplug suppressed, as it is found that the overpressure plug, and cut off power supply, after the water level drop to normal hydraulic press to stop work. After being repaired back to normal, can continue to work. Check the water (with soap and water Gas) Tanks, air valve, trachea is flat, if you have any cold frost condensation ( Water) Conditions, gas leakage is serious, should be timely repair. If you want to thaw, disable open flame. 7, axial plunger pump oil level must be maintained, the general should remain on the surface of the oil immersion of six to seven over ten of the position, found the oil shortage, should be filling in time, in order to ensure normal operation of the equipment. 8, system security on exposed moving parts are set inside the shield. Boot operation is not allowed in the case of the removing of the shield. Under special circumstances have strict supervision and prevention measures in detail. 9, this system should be set up around the activities of protective railings. Shall not be removed during normal operation or movement. The operators shall not enter in the operation. 10, this system for high voltage equipment, the corresponding management and operation of container need to strictly implement the relevant provisions of the state. Keywords: oil pump power plant, the axial plunger pump manufacturers, variable plunger pump manufacturers
Dongguan Suncenter Fluid Control Equipment Co., Ltd works very hard to understand your objectives, then create a program that can help you meet them.
If you are ready to stop the problem of hydraulic pressure pump and go back to normal, contact us at Suncenter Fluid Control Equipment. Dongguan Suncenter Fluid Control Equipment Co., Ltd is ready to help you out.
gas booster continued to evolve to having strong manufacturers develop huge marketers and people came to value their opinions about what to buy.
Custom message
Chat Online 编辑模式下无法使用
Leave Your Message inputting...